13.53 Settings when Infrared Cut Filter Not Inserted Camera Control Command Type 2
Function Sets the status when infrared cut filter is not inserted.
Command 00B5h
Length 1 byte. Parameter
Value 0h
Status None
Reference
Format of Control Code
d0 d1 d2 d3 d4 d5 d6
Header Device Num Command Parameter End mark
FFh 30h 3Xh 00h B5h 30h EFh
Answer Format
d0 d1 d2 d3 d4 d5
Header Device Num Error Code End mark
FEh 30h 3Xh e0 e1 EFh
Error Flag indicates in 2 figures hexadecimal and returns ASCII code value.
Example: e0 e1
In case of No Error : 00000000B 00h 30h 30h
In case of Busy : 00010000B 10h 31h 30h
In case of Parameter Error : 01010000B 50h 35h 30h
In case of Mode Error : 10010000B 90h 39h 30h
Condition of Error flag to be set
Busy •Filter insertion/removal operation is in progress
Parameter Error •In case of assigned parameter illegal
Mode Error •Not in status of Camera ON.
•Not in status of Host Control Mode.