Programmers User Manual

124
13.62 Dome Mode Setting Verification Camera Control Command Type 1
Function Returns the dome mode setting value.
Command 00BDh
Length 2 byte Parameter
Value 01h
Length 2 byte Status
Range 00h~03h
Reference •Dome mode setting value
00h: Select cam path 0 to 9
01h: Select cam path 0 to 8
02h: Select cam path 0 to 7
03h: Select cam path 0 to 6
•Setting value of cam path 0 to 9
0: INF 1: 450cm 2: 201cm 3: 120cm 4: 80cm
5: 40.7cm 6: 9.2cm 7: 1cm
Format of Control Code
d0 d1 d2 d3 d4 d5 d6 d7
Header Device Num Command Parameter End mark
FFh 30h 3Xh 00h BDh 30h 31h EFh
Answer Format
No Error
d0 d1 d2 d3 d4 d5 d6 d7
Header Device Num Error Code Status End mark
FEh 30h 3Xh 30h 30h s0 s1 EFh
Setting value indicates in 2 figures hexadecimal and returns ASCII code value
Noise Reduction s0 s1
Doom setting value : 00h 30h 30h
Doom setting value : 01h 30h 31h
Doom setting value : 02h 30h 32h
Doom setting value : 03h 30h 33h
Generated Error
d0 d1 d2 d3 d4 d5
Header Device Num Error Code End mark
FEh 30h 3Xh e0 e1 EFh
Error Flag indicates in 2 figures hexadecimal and returns ASCII code value
Example: e0 e1
In case of Parameter Error : 01010000B 50h 35h 30h
In case of Mode Error : 10010000B 90h 39h 30h
Conditions for setting of error flag
Parameter Error •In case of assigned parameter illegal
Mode Error •Not in status of Camera ON
•Not in status of Host Control Mode