Programmers User Manual

143
14.16 Operation Status 3 Request System Control Command Type 1
Function Returns operation status 3.
Command 0086h
Parameter 1h
Length 4 byte Status
Value Based on the operation status (16 bit) value indicating the
internal status.
Reference The following statuses are indicated when each bit in the status is 1.
(MSB)
b15 Not used (undetermined value)
b14 Not used (undetermined value)
b13 Not used (undetermined value)
b12 Not used (undetermined value)
b11 Not used (undetermined value)
b10 Not used (undetermined value)
b9 Not used (undetermined value)
b8 Not used (undetermined value)
b7 Displayed on screen (central control) 0: off, 1: on
b6 Displayed as user text 0: off, 1: on
b5, 4 Displayed date b5 b4
0 0 : off
0 1 : Displayed as style 1
1 0 : Displayed as style 2
b3, 2 Displayed time b3 b2
0 0 : off
0 1 : Displayed as style 1
1 0 : Displayed as style 2
b1 Date setting completed 0: Not set 1: Setting completed
b0 Time setting completed 0 :Not set 1: Setting completed
(LSB)
•The b0, b1 information is identical to the information in 14-15. Extended
Operation Status Request (b16, b17).
Format of Control Code
d0 d1 d2 d3 d4 d5 d6
Header Device Num Command Parameter End mark
FFh 30h 3Xh 00h 86h 31h EFh