Programmers User Manual

160
14.29 Host Control Mode System Control Command Type 1
Function To set host control mode.
Command 0090h
Length 1 byte Parameter
Value 0h
Status None
Reference •At the moment of power ON, default sets Local Control Mode.
•To be able to control by only host computer through RS-232C and unable to
control by remote controller.
Local Control Mode flag in operation status by this command is cleared to
0.
•In case to control by remote controller in Host Control Mode, by using
remote control through function, possible to control through computer.
•In case of entering ID number of remote control or Set number of preset
during issuing this command, each input status is forced to release.
Format of Control Code
d0 d1 d2 d3 d4 d5 d6
Header Device Num Command Parameter End mark
FFh 30h 3Xh 00h 90h 30h EFh
Answer Format
d0 d1 d2 d3 d4 d5
Header Device Num Error Code End mark
FEh 30h 3Xh e0 e1 EFh
Error Flag indicates in 2 figures hexadecimal and returns ASCII code value.
Example: e0 e1
In case of No Error : 00000000B 00h 30h 30h
In case of Parameter Error : 01010000B 50h 35h 30h
In case of Mode Error : 10010000B 90h 39h 30h
Condition of Error flag to be set
Parameter Error •In case of assigned illegal parameter.
Mode Error •In case of operating MENU by Local Mode.