Programmers User Manual

174
14.40 Command Termination Notification Setting System Control Command Type 1
Function To set command termination notification ON/OFF after command type 2
completion.
Command 0094h
Length 1 byte
0h: OFF (not Notify)
Parameter
Value
1h: ON (Notify)
Status None
Reference •At the moment of power ON, to OFF by default.
•Command termination notification comes out to effective at the command
after issuing this command.
•See Communication Timing Diagram (3.3), Function of Command
Termination Notification (6), Classification by Execution Format (10.2).
Format of Control Code
d0 d1 d2 d3 d4 d5 d6
Header Device Num Command Parameter End mark
FFh 30h 3Xh 00h 94h p0 EFh
Command termination notification ON/OFF indicates in ASCII code 1 byte.
Example: to notify command termination notification p0
01h 31h
Answer Format
d0 d1 d2 d3 d4 d5
Header Device Num Error Code End mark
FEh 30h 3Xh e0 e1 EFh
Error Flag indicates in 2 figures hexadecimal and returns ASCII code value.
Example: e0 e1
In case of No Error : 00000000B 00h 30h 30h
In case of Parameter Error : 01010000B 50h 35h 30h
In case of Mode Error : 10010000B 90h 39h 30h
Condition of Error flag to be set
Parameter Error •In case of assigned parameter except 0h or 1h.
Mode Error •Not in status of Camera ON.
•Not in status of Host Control Mode.