Manual

CeilingVIEW HD-18 DocCAM Series
CeilingVIEW HD-18 DocCAM Manual - Document Number 342-0195 Rev. B 15 of 24
CeilingVIEW HD-18 DocCAM Connectors and Pin-out Detail:
The connections on the top of the camera enclosure are as follows:
1) One (1) RJ-45 connector for RS-232 communication and IR Out
2) One (1) RJ-45 connector for Power/Video to be connected to the Quick-Connect HD-18 SR or Quick-Connect
DVI/HDMI SR Interface.
x RS-232/IR OUT RJ-45:
This jack provides for RS-232 bi-directional control and IR Out for IR Forwarding of 3
rd
party IR Remotes to
control codecs. Generally, the main camera in a system may have the requirement for IR Forwarding, but for
added flexibility, the CeilingVIEW HD-18 also can forward the IR commands from other IR Remotes (for
example Polycom, LifeSize and Cisco/TANDBERG C-Series codec remotes).
Pin Function
1) Unused
2) Unused
3) Unused
4) IR Output (Diff Signal to Quick-Connect)
5) IR Ground (Diff Signal to Quick-Connect)
6) GND
7) RXD (from TXD of control source)
8) TXD (to RXD of control source)
x Power/Video RJ-45:
The Power/Video Port supplies power to the CeilingVIEW HD-18 DocCAM and returns HSDS (differential HD
Video) up to 100’ (30.5m).
Pin Function
1) Power+
2) Power-
3) Y+
4) PB+
5) PB GND
6) Y GND
7) PR+
8) PR-
12345678