User guide

CeilingVIEW SD CCU
Vaddio CeilingVIEW SD CCU Installation and User Guide - Document 341-769 Rev. A
Page 15 of 16
Appendix 3 (continued) Rear Panel Connections:
Power Supply Input:
36V 2.78 Amp power supply on a 5.5mm OD x 2.5mm ID connector.
RS-232 IN on RJ-45:
RS-232 Input from ProductionVIEW or other external RS-232 controller. NOTE: Daisy-chain control is not
supported with any of the CCU products.
RS-232 OUT / G/L Out on RJ-45:
RS-232 on Cat. 5 provide control to the CeilingVIEW Camera Module. NOTE: Genlock (G/L) is not
supported with CeilingVIEW CCU systems.
Tally on 2-pin Phoenix type connector:
Contact Closure lights LED on front panel allowing indication of which QCCU/camera combination is active in
a multi-camera/QCCU installation.
Unused Ports for the CeilingVIEW CCU Systems:
Power - RJ-45
G/L Input - BNC-F
Camera Feature Switches: All of these switches should be in the down position.
Y-Gain
Distance
Video Outputs
Video RJ-45
Appendix 4:
Control Pin-outs for the Quick-Connect CCU
RS-232 IN Connector RJ-45
Pin
Signal - RS-232
1) Not Used
2) Not Used
3) Not Used
4) Not Used
5) Not Used
6) GND
7) RXD (from TXD)
8) TXD (to RXD)
RS-232 / G/L OUT Connector RJ-45
Pin
Signal - RS-232
1) Not Used
2) Not Used
3) Not Used
4) Not Used
5) Not Used
6) GND
7) TXD (to RXD)
8) RXD (from TXD)
+ G
12345678
12345678