CABLING REQUIREMENTS
For the DomeVIEW 70 Outdoor Pendant Dome and DomeVIEW 50iR Outdoor Pendant Dome that use the
EZCamera Cabling system, the cabling requirements are as follows:
One (1) - Cat. 5 Cable for Power/Video
One (1) - Cat. 5 Cable for RS-232 control input
One (1) - Cat 5 Cable for RS-232 control output for daisy chaining
One (1) - Pair unshielded cable (16AWG or 18AWG) for 24 VAC power supply (100’ / 30.48m Max)
(See system drawings on pages 13)
For the Outdoor Pendant Mount Dome Enclosures that do not use the EZCamera Cabling system, the native
connections on the cameras and original power supply must be used. Custom cables for camera power (12
VDC), heater/blower power (24 VAC), video (S-video or composite video) and control signaling must be
fabricated.
Note: The RS-232 requires at least 5 wires – preferably paired for TXD and RXD as well as DTR/DSR for Sony control daisy
chain and CTS/RTS for Canon control daisy chain. The native control connections of the Sony EVI-D70 uses the 8-pin mini-din
female connector for RS-232 in and RS-232 out, and the Canon uses a proprietary 20-pin connector and also has an adapter
available to convert the 20-pins into 8-pin mini-din although it is pin differently than the Sony 8-pin mini-din. Please see power
supply cable extension disclaimer above.
GENERAL SPECIFICATIONS
Mechanical
Enclosure: Dual Shell Design; UV Resistant ABS Plastic Outer shell
Dome: .118” Cell-cast Acrylic
Hardware: Heavy-gauge steel and Aluminum construction
Weight: 5.26 lbs with heater/blower - camera not included
Electrical
Input Voltage: 24 VAC +/- 10%
Power Requirements 1.8 amps (1 heater, 1 blower) - camera not included
Power Supply: Power Supply Included, Primary 120VA 60Hz,
Secondary 24VAC, 50VA
Blower: Two (2) 24.8 CFM @ .006 watts,
Continuous operation at .16 amps
Heater: One (1) 40-watt heater
Operating Range: With Heater Blower Kit -20°F to 120°F (33°F to 100°F without)
Certifications
Designed to meet NEMA-4 guidelines and
Independently certified to IP66 requirements with proper installation
Optional Accessories:
998-9300-000 Curved Wall Mount
998-9300-001 Curved Wall Mount and Pole Mount Kit
998-9300-002 Ceiling Pendant Mount
451-2000-024 PowerRite 24 VDC power supply
Note: see page 8 for cabling distance using standard and optional power supplies