A-C1Z-100-12 (1) 3CCD Color Video Camera Command List Version 1.
Table of Contents VISCA RS-232C/RS-422 Commands ........................ 3 Overview of VISCA ..................................................... 3 VISCA Communication Specifications........................ 4 VISCA Device Setting Command ............................... 6 VISCA Command/ACK Protocol................................. 7 VISCA Camera-Issued Messages .............................. 8 BRC-300/P Commands ............................................. 9 BRC-300/P Command List (1/4) ..................
VISCA1) RS-232C/RS422 Commands Use of RS-232C/RS-422 control software based upon this command list may cause malfunction or damage to hardware and software. Sony Corporation is not liable for any such damage. Each VISCA device has a VISCA IN and VISCA OUT connector. Set the DTR input (the S output of the controller) of VISCA IN to H when controlling VISCA equipment from the controller. Fig.
VISCA Communication Specifications VISCA packet structure The basic unit of VISCA communication is called a packet (Fig. 2). The first byte of the packet is called the header and comprises the sender’s and receiver’s addresses. For example, the header of the packet sent to the BRC-300/P assigned address 1 from the controller (address 0) is hexadecimal 81H. The packet sent to the BRC-300/P assigned address 2 is 82H. In the command list, as the header is 8X, input the address of the BRC-300/P at X.
Command and inquiry Socket number z Command When command messages are sent to the BRC-300/P, it is normal to send the next command message after waiting for the completion message or error message to return. However to deal with advanced uses, the BRC-300/P has two buffers (memories) for commands, so that up to two commands including the commands currently being executed can be received.
VISCA Device Setting Command Before starting control of the BRC-300/P, be sure to send the Address command and the IF_Clear command using the broadcast function. For VISCA network administration z Address Sets an address of a peripheral device. Use when initializing the network, and receiving the following network change message. z Network Change Sent from the peripheral device to the controller when a device is removed from or added to the network.
VISCA Command/ACK Protocol Command Command Message Reply Message Comments General Command 81 01 04 38 02 FF (Example) 90 41 FF (ACK)+90 51 FF (Completion) 90 42 FF 90 52 FF Returns ACK when a command has been accepted, and Completion when a command has been executed. 81 01 04 38 FF 90 60 02 FF (Syntax Error) Accepted a command which is not supported or a command lacking parameters.
VISCA Camera-Issued Messages ACK/Completion Messages Command Command Message Comments ACK z0 4y FF (y:Socket No.) Returned when the command is accepted. Completion z0 5y FF (y:Socket No.) Returned when the command has been executed. z = Device address + 8 Error Messages Command Command Message Comments Syntax Error z0 60 02 FF Returned when the command format is different or when a command with illegal command parameters is accepted.
BRC-300/P Commands BRC-300/P Command List (1/4) Command Set Command Command Packet Comments AddressSet Broadcast 88 30 01 FF Address Set IF_Clear Broadcast 88 01 00 01 FF I/F Clear 8x 2p FF p: Socket No (=1 to 2) CAM_Power On 8x 01 04 00 02 FF Power On/Off Off 8x 01 04 00 03 FF CAM_Zoom Stop 8x 01 04 07 00 FF Tele(Standard) 8x 01 04 07 02 FF CommandCancel CAM_DZoom CAM_Focus CAM_AFMode CAM_ZoomFocus CAM_WB Wide(Standard) 8x 01 04 07 03 FF Tele(Variable) 8x 01 04 07 2p FF W
BRC-300/P Command List (2/4) Command Set Command Command Packet Comments CAM_RGain Reset 8x 01 04 03 00 FF Default R Gain setting Up 8x 01 04 03 02 FF CAM_BGain CAM_AE CAM_SlowShutter CAM_Shutter CAM_Iris CAM_Gain CAM_Bright CAM_ExpComp CAM_BackLight CAM_SpotAE CAM_Aperture Down 8x 01 04 03 03 FF Direct 8x 01 04 43 00 00 0p 0q FF R Gain Direct pq (=00 to FF) Reset 8x 01 04 04 00 FF Default B Gain setting Up 8x 01 04 04 02 FF Down 8x 01 04 04 03 FF Direct 8x 01 04 44 00 00 0
BRC-300/P Command List (3/4) Command Set Command Command Packet Comments CAM_PictureEffect Off 8x 01 04 63 00 FF Picture Effect setting Neg.
BRC-300/P Command List (4/4) Command Set Command Command Packet Comments Pan-tiltLimitSet Limit Set 8x 01 06 07 00 0W 0Y 0Y 0Y 0Y 0Y 0Z 0Z 0Z 0Z FF W: 1 UpRight 0:DownLeft* YYYYY: PanLimit Position 0x00000 (Center) 0x08A58 (Left End) 0xF75A8 (Right End) ZZZZ: TiltLimit Position 0x00000 (Center) 0x493D (Up End) 0xE796 (Down End) Limit Clear Analog-Card setup CAM_ImgFlip CAM_DataMix CAM_PanReverse CAM_TiltReverse Cmd_Tally Cmd_PT_M_Speed Cmd_Disp_Info Cmd_dzm_chg 8x 01 06 07 01 0W 07 0F 0F 0F
BRC-300/P Inquiry Command List (1/2) Inquiry Command Command Packet Inquiry Packet Comments CAM_PowerInq 8x 09 04 00 FF y0 50 02 FF On y0 50 03 FF Off (Standby) CAM_ZoomPosInq 8x 09 04 47 FF y0 50 0p 0q 0r 0s FF pqr: Zoom Position CAM_DZoomModeInq 8x 09 04 06 FF y0 50 02 FF D-Zoom On y0 50 03 FF D-Zoom Off CAM_DZoomC/SModeInq 8x 09 04 36 FF y0 50 00 FF Combine Mode y0 50 01 FF Separate Mode CAM_DZoomPosInq 8x 09 04 46 FF y0 50 00 0 0p 0q FF pq: Digital Zoom Position CAM_FocusMo
BRC-300/P Inquiry Command List (2/2) Inquiry Command Command Packet Inquiry Packet Comments CAM_MemoryInq 8x 09 04 3F FF y0 50 pp FF pp: Memory number last operated CAM_MENUInq 8x 09 06 06 FF y0 50 02 FF On y0 50 03 FF Off CAM_IDInq 8x 09 04 22 FF y0 50 0p 0q 0r 0s FF pqrs: Camera ID CAM_VersionInq 8x 09 00 02 FF y0 50 00 20 mn pq rs tu vw FF mnpq: Model Code (04xx) rstu: ROM version CAM_TitleModeInq 8x 09 7E 01 13 FF y0 50 02 FF On y0 50 03 FF Off CAM_PresetTitleModeInq 8x 09 7
BRC-300/P Block Inquiry Command List Lens control system inquiry ...........................
Camera control system inquiry commands ..
Other inquiry commands .........................................
Enlargement Function Query Command ...............
VISCA Command Setting Values Exposure Control (1/2) Shutter Speed Iris DATA IRIS (F1.6) BRC-300 BRC-300P [sec] [sec] 15 1/10000 1/10000 DATA F No. IRIS 11 F1.6 10 F2.0 14 1/6000 1/6000 0F F2.4 13 1/4000 1/3500 0E F2.8 12 1/3000 1/2500 0D F3.4 11 1/2000 1/1750 0C F4 10 1/1500 1/1250 0B F4.8 0F 1/1000 1/1000 0A F5.6 0E 1/725 1/600 09 F6.8 0D 1/500 1/425 08 F8 0C 1/350 1/300 07 F9.
Exposure Control (2/2) Exposure Adjustment Bright Comp Value AGC IRIS (F1.6) GAIN F No. 17 18dB F1.6 0E 16 15dB F1.6 0D +9dB +6 +7.5dB +5 +4 DATA DATA +10.5dB Display +7 15 12dB F1.6 0C 14 9dB F1.6 0B +6dB 13 6dB F1.6 0A +4.5dB +3 12 3dB F1.6 09 +3dB +2 11 0 F1.6 08 +1.5dB +1 10 0 F2.0 07 0dB 0 0F 0 F2.4 06 – 1.5dB –1 0E 0 F2.8 05 – 3dB –2 – 4.5dB –3 0D 0 F3.4 04 0C 0 F4 03 – 6dB –4 0B 0 F4.8 02 – 7.5dB –5 0A 0 F5.
Zoom Ratio and Zoom Position (for reference) Pan/Tilt Position (for reference) Pan Optical Zoom Zoom Ratio × 12 Lens Angle Left Right (Degree) YYYYY YYYYY 0000 ×1 0 00000 00000 1982 ×2 10 00823 FF7DD 24E2 ×3 20 01046 FEFBA 2BC9 ×4 30 01869 FE797 3099 ×5 40 0208C FDF74 343D ×6 50 028AF FD751 3724 ×7 60 030D2 FCF2E 3988 ×8 70 038F5 FC70B 3B8B ×9 80 04118 FBEE8 3D43 ×10 90 0493B FB6C5 3EBB ×11 100 0515E FAEA2 ×12 110 05981 FA67F 120 061A4 F9
Pan/Tilt Status Code List P Q R S 0--- ---- 0--- ---1 Pan direction turns to left side 0--- ---- 0--- --1- Pan direction turns to right side 0--- ---- 0--- -1-- Tilt direction turns to upper side 0--- ---- 0--- 1--- Tilt direction turns to lower side 0--- ---- --00 ---- Pan direction operates normal 0--- ---- --10 ---- Pan mechanism operates defective 0--- --00 0--- ---- Tilt direction operates normal 0--- --10 0--- ---- Tilt mechanism operates defective 0--- 01-
Revision History Version Item 1.00 1.