Technical data

5 Boiler Installation Sequence 5
Instructions for installation and servicing aquaPLUS VUI 362-716
5.7 Gas supply
Connect the 15 mm compression gas service cock (1)
and 22 mm copper outlet tail (3) as supplied with the
appliance (2) and tighten.
Connect a gas supply pipe of not less than 22 mm
diameter to the copper tail.
Tighten all connections.
(Ensure the gas supply pipework is adequately sized
such that a 20 mbar gas pressure is available at the
boiler inlet at full flow rate).
Fig. 5.6: Fitting the gas connection aquaPLUS
I
0
3
1
2
5.8 Cold water mains inlet and hot water outlet
Flush all foreign matter from the mains supply before
connecting to the boiler.
Connect the cold water service valve (1) to the cold
inlet water connection (3) of the appliance with the
washer (2) provided and tighten.
Connect the 15 mm cold water inlet pipe copper tail
(4) to the cold water service valve (1) and tighten.
Connect the 15 mm hot water outlet copper tail (6) to
the hot water outlet connection of the appliance (8)
with the washer provided (7) and tighten.
Note: The hot water outlet union nut is packed in
with the PRV fitting pack.
Connect the cold water service pipe and hot water
outlet pipework to the copper tails.
Fig. 5.7: Fitting the hot and cold water connections aquaPLUS
I
0
1
2
3
4
6
7
8
834702_33GB_012005.qxd 09.03.2005 16:26 Uhr Seite 16