Installation Instructions
5 Assembly and installation
10 Installation instructions aroTHERM 0020147164_04
▶ When transporting the product, two
people should lift it.
▶ Observe the product weight stated in the
technical data.
▶ When transporting heavy loads, observe
the applicable directives and regulations.
Caution.
Risk of material damage due to incorrect
transportation.
Regardless of the mode of transport, the heat
pump must never be tilted by more than 45°.
Otherwise, this may lead to malfunctions in
the coolant circuit during subsequent opera-
tion. In the worst case scenario, this may lead
to a fault in the whole system.
▶ During transport, do not tilt the heat pump
by any more than the maximum angle of
45°.
1. Use the transportation belt to carry the product to the
final installation site.
2. Only lift the product from the back and side where the
hydraulic connections are located.
3. When transporting the product using a hand truck, se-
cure the product using a belt.
4. In order to avoid scratches and damage, protect the
sides of the product that come into contact with the
hand truck.
5.1.1.2 Unpacking the product
13mm
1
2
3
4
B
A
D
E
C
1. Remove the accessory (2).
2. Remove the documentation supplied (1).
3. Remove the transport belt (4).
4. Carefully remove the packaging and padding without
damaging the product (3).
5. Remove the screws from the pallet at the front and rear
of the product.
5.1.1.3 Checking the scope of delivery
▶ Check the contents of the packaging units
Quant-
ity
Description
1 Condensate discharge
1 Bag with seals
4 Vibration-isolating feet
1 Purge hose
5.1.2 Complying with clearances and installation
clearances
5.1.2.1 Unit dimensions and connection
dimensions
120
120
74 0
980
408
840*
386
VWL 55/2 A 230 V
386
11
* Size increases by 45 mm
when using the vibration