Operation Manual

Installation instructions – auroMATIC 560 0020008427_014
4.4 Installing the controller housing
The controller is designed to be mounted on a wall and
is equipped with System ProE terminal strips. These ter-
minals must be used for all connections made at the in-
stallation site.
Fig. 4.2 Opening the controller housing
The cover consists of two parts, which can be removed
separately.
As shown in Fig. 4.2, pull the lower front cover off of
the controller housing.
C1/C2
C1 C2
KOL1
21
SP1
21
SP2
21
SP3
21
Ertrag
21
KOL2
21
230 V~
PE N L
KOL1-P
PE N L
LEG/BYP
PE N L
LP/UV1
PE N L
EP
21
KOL2-P/Z P
PE N L
12
Fig. 4.3 Fastening the controller housing
Mark the position of both holes (1 and 2) and drill the
bore holes.
Select the wall plugs to suit the state of the wall, and
screw the controller housing on tightly.
ProE-system wiring
C1/C2
C1 C2
KOL1
21
SP1
21
SP2
21
SP3
21
Ertrag
21
KOL2
21
230 V~
PE N L
KOL1-P
PE N L
LEG/BYP
PE N L
LP/UV1
PE N L
EP
21
KOL2-P/Z P
PE N L
3
Fig. 4.4 Fold-up the control panel
Fold the control panel towards the top.
Wire the controller according to the selected hydraulic
plan (see Section 5.1).
Secure all cables with the accompanying cable clamps
(3).
Fold the control panel back down.
Attach the front cover again.
5 Electrical installation
The electrical connection may only be carried out by an
approved specialist company.
e
Danger!
Risk of fatal electric shock from touching live
connections. Before working on the appliance,
turn off the power supply and secure against
restart.
a
Caution!
The circuit board can be damaged if short
circuited through the connection leads. For
safety purposes, a max. of 30 mm of insulation
may be removed from the ends of 230 V leads
which will be connected to ProE plugs. If more
insulation is removed, there is a risk of short
circuiting the circuit board.
Caution!
When exchanging the controller in an existing
system, sensor-curve characteristics should be
taken into consideration (see Sec. 11), and the
sensors should be replaced if necessary!
4 Assembly
5 Electrical installation