6 Start-up
6.1 Setting system parameters
Certain system parameters have to be set in order to
optimise the system for the respective conditions. These
parameters are all together on one operating level and
should only be set by the heating engineer.
You can access this operation level by pressing the pro-
gramming button "P" for roughly 3 seconds.
Display Turn the dial to adjust Setting range Factory setting
Changing the hydraulic plan 1, 2, 3 1
Adjusting the flow rate in l/min.
Transfer the value set at the solar station
flow rate limiter taking the unit used by this
specific flow rate limiter into account!
0 –165 l/min 3.5 l/min
Resetting the solar yield.
The solar yield is reset to 0 by turning the
dial to 1.
--
Resetting the operating hours.
The operating hours are reset to 0 by turning
the dial to 1.
--
Setting the max. temperature for cylinder 1 20 to 90 °C 75 °C
Table 6.1 System parameters
a
Caution!
The maximum permissible temperature of the
cylinder used (MAXT 1) must not be exceeded.
All system parameters can then be called up consecu-
tively by clicking the dial. You can specify the required
values by turning the dial. The value set can be saved by
clicking the dial.
When you press the P button, the display returns to
basic operating level without saving the adjusted value.
The following table gives an overview of all system pa-
rameters and their factory settings: