Display Actuators/sensor values Test procedure
Cylinder temperature display for cylinder sensor 1
Cylinder temperature display for cylinder sensor 2
Temperature display for cylinder sensor 3
Temperature display for collector sensor 1
Temperature display for collector sensor 2
Temperature display for return flow (yield sensor)
Table 7.1 Actuators and sensors (continued)
You can check the visual display by clicking on the dial
again.
2
Fig. 7.1 Check visual display
With another click, the current version of the control-
ler’s software is displayed.
Fig. 7.2 Controller software version
You can exit the service/diagnostic level by pressing the
programming button.