Installation Instructions
4 On-roof fitting and installation
18 Installation manual auroTHERM exclusive 0020077994_02
Conditions: Collector rows: 3
A
B
B
A
▶ Use the following table to put together the components for installation.
Number of VTK 1140/2 collectors per row 1 2 3 4 5 6 7
Components Required sets
VTK installation set (basic set)
3
1
VTK installation set (extension set)
− 3 6 9 12 15 18
Roof bracket set type P (pantile)
A
1
2
2
2
3
2
4
2
5
2
6
2
7
2
Roof bracket set type S (slate)
Roof bracket set type S, flat (slate)
Roof bracket set type P (pantile)
B
2
2
4
2
6
2
8
2
10
2
12
2
14
2
Roof bracket set type S (slate)
Roof bracket set type S, flat (slate)
Rail set (2), VTK 1140/2
3 6 9 12 15 18 21
1
1 set per row; the collectors are connected together using the extension set – if the rows are also connected together so that
they are flat-sealed.
2
Valid up to 700 m above sea level