Technical data

23Operating Manual geoTHERM exclusive VWS 0020071929_00
5.6 Special functions
Special functions can be selected only from the basic
display. To do so press the left-hand dial
.
To change the parameter, you must turn the
dial. The
following special functions can be selected:
Energy saving function: Press
dial once.
• Party function: Press
dial twice.
• One-time charging: Press
dial 3 x.
• Cooling operation: Press
dial 4 x
To activate one of the functions, you merely have to se-
lect it. In the energy saving function it is additionally
necessary to enter the time until which the energy sav-
ing function (regulation to set-back temperature) is to
apply.
The basic display appears either after the function has
elapsed (reaching the time) or by pressing the
dial
again.
Display shown Description
We 16.02.08 9:35
Energy saving enabled
>Select end time
Saving function:
With the saving function you can set back the heating times for a set-
table period.
Enter the time for the end of the saving function in the format hh:mm
(hour:minute).
We 16.02.08 9:35
Party function enabled
Party function:
With the party function you can continue the heating and hot water
times beyond the next switch-off time up to the next heating start.
The party function can only be used for the heating circuits or hot
water circuits for which the operating mode "Auto" or "ECO" is set.
We 16.02.08 9:35
one-time
DHW tank loading enabled
One-time charging:
This function allows you to charge the hot water cylinder once, re-
gardless of the current time program.
Table 5.2 Special functions