Technical data

29Operating Manual geoTHERM exclusive VWS 0020071929_00
7 Appendix
7.1 Technical data
a
Caution!
R 407 C is a chlorine-free coolant which
does not affect the ozone layer. Never-
theless, servicing work on the cooling
circuit should only be carried out by au-
thorised specialists.
Description Unit VWS 63/2 230 V VWS 83/2 230 V VWS 103/2 230 V
Article number - 0010007274 0010007275 0010007276
Height with connections
Width
Depth without pillars
Depth with pillars
mm
mm
mm
mm
1930
600
650
840
Total weight
- With packaging
- Without packaging
- Ready for operation
Transport weight
- Domestic hot water cylinder module
- Heat pump module
kg
kg
kg
kg
kg
231
216
402
100
106
239
224
411
100
114
242
227
415
100
117
Rated voltage
- Heating circuit/Compressor
- Control circuit
- Auxiliary heating
-
1/N/PE 230 V 50 Hz
1/N/PE 230 V 50 Hz
1/N/PE 230 V 50 Hz
Fuse, slow-blow
- Unblocked mains supply
Alternative operation (as-delivered
condition 4 kW)
A
16/20 25/25
Parallel operation A
25/35 35/50
dual-circuit supply, heat pump tariff
- Compressor, single
- Auxiliary heating 2/4 kW, single
A
A
16
16/20
25
16/20
25
16/20
Dual-circuit supply, special tariff
- Alternative operation (as-delivered
status 4kW)
A
16/20 25/25 25/25
Parallel operation
- Pumps and controllers
A
A
25/35
4
35/50
4
35/50
4
Start-up current
- Without start-up current limiter
- With start-up current limiter
A
A
58
< 45
76
< 45
97
< 45
Rated output
- Min. for B-5W35
- Max. for B20W60
- Auxiliary heating
kW
kW
kW
1.4
2.8
2/4
1.9
4.0
2/4
2.4
4.9
2/4
EN 60529 level of protection - IP 20
Hydraulic connections
- Heating circuit flow and return
- Heat source flow and return
- Cold/hot water
mm
mm
mm
G 1 1/4", Ø 28
G 1 1/4", Ø 28
R 3/4"
Table 7.1 Technical data
Appendix 7