Installation Instructions

Technical data
Installation instructions VRC 470f 0020124645_00 49
14
14 Technical data
i
The range of radio transmission inside build-
ings is heavily dependent on the local condi-
tions (e.g. the design and structure of the
building). Consequently, an indoor range of
25m cannot always be guaranteed. Outside
enclosed spaces (outdoors) the range is more
than 100 m.
14.1 VRC 470f controller
Designation Unit VRC 470f
Operating voltage U
max
V 4 x 1.5 V (AA)
Battery life (alkaline) Years Approx. 1.5
Protection type - IP 20
Protection class - III
Max. permissible
ambient temperature
°C 50
Transmission frequency MHz 868
Transmission power mW
< 10
Range:
Outdoors m
> 100
Inside building m
Approx. 25
Height mm 115
Width mm 147
Depth mm 50
Tab. 14.1 Technical data of VRC 470f radio controller
14.2 Radio receiver unit
Designation Unit Radio receiver unit
Operating voltage U
max
V24
Current consumption mA < 60
Protection type - IP 20
Protection class - III
Max. permissible
ambient temperature
°C 50
Transmission frequency MHz 868
Transmission power mW
< 10
Range:
Outdoors m
> 100
Inside building m
Approx. 25
Height mm 115
Width mm 147
Depth mm 50
Tab. 14.2 Technical data of radio receiver unit
14.3 Outside temperature sensor/transmitter
Designation Unit
Outside tempera-
ture sensor/trans-
mitter VR 21
Power supply -
From solar cell with
energy store
Reserve power supply
(with full energy store)
Days Approx. 20
Protection type - IP 44
Protection class - III
Permissible operating tempera-
ture
°C - 35 … + 60
Transmission frequency MHz 868
Transmission power mW
< 10
Range:
Outdoors m
> 100
Inside building m
Approx. 25
Height mm 110
Width mm 76
Depth mm 41
Tab. 14.3 Technical data of VR 21 outside temperature sensor/
transmitter