For the operator / for the expert technician Operating and Installation Manual VRT 392f Room thermostat with radio transmission GB VRT 392f
For the owner Operating manual VRT 392f Room thermostat VRT 392f Contents Equipment properties ................................................4 Application ............................................................................4 Product specifications ........................................................4 1 1.1 1.2 1.3 1.4 Notes on the documentation ......................... 5 Storage of the documents ....................................5 Symbols used .........................................
Equipment properties Equipment properties Application The VRT 392f is a programmable room temperature controller for the heating system. The VRT 392f also controls the hot water generation. You can use the VRT 392f to specify various room target temperatures (programming) — for different times of the day and for different days of the week. In automatic mode, the VRT 392f controls your heating in accordance with this input (see Fig. 0.1).
Notes on the documentation 1 Safety 2 1 Notes on the documentation The following notes are intended to help you throughout the entire documentation. Further documents apply in combination with this operating manual. We accept no liability for any damage caused by failure to observe these instructions.
3 Instructions for operation 3 Instructions for operation 3.1 Intended use The VRT 392f is a state-of-the-art device which has been constructed in accordance with the standard safety regulations. However, in the event of improper use or use not as intended, impairment of the equipment and other items can arise.
Operation 4 4 Operation h Note Have your expert technician explain the operator input for the controller once the installation is complete. This will prevent the settings being changed unintentionally. 4.1 Overview operating and display front 1 Th. 12.01.06 11:46 19.0 °C Auto VRT 392f 3 Fig. 4.1 2 Overview of operator control and display panel Key 1 Display 2 Operating element of the right-hand dial 3 Operating element of the left-hand dial Fig. 4.1 shows the default display.
4 Operation 4.2 Overview of the displays The display and input parameters (operating values) of the VRT 392f are shown on the various screens. The screens are sub-divided into: – Default display (Fig. 4.8) – Basic display (Fig. 4.2) – Display/input screens for certain parameters in the operator level – Display/input screens for operating and system-specific parameters at the expert technician level All the screens are divided into three areas. Th. 12.01.06 11:46 1 HC1 21.0 °C Auto Hot water 56.
Operation 4 4.3.1 Show various screens By turning the left-hand dial you can page through the individual screens of the display like a book. 4.3.2 Changing parameters Turn the right-hand dial to scroll through the parameters within the screen. Example: You are now located in the basic display. A description of how to navigate to the basic display is provided in Section 4.3.3. The position is indicated by the cursor (see Fig. 4.5). If a parameter (e.g.
4 Operation Click the right-hand dial. Turn the right-hand dial to show the possible values. The parameter value marked by the cursor is inversely displayed. Th. 12.01.06 11:46 HC1 21.0 °C Auto Hot water 56.0 °C Auto Th. 12.01.06 11:46 HC1 21.0 °C Auto Hot water 56.0 °C Auto Th. 12.01.06 11:46 HC1 21.5 °C Auto Hot water 56.0 °C Auto Th. 12.01.06 11:46 HC1 22.0 °C Auto Hot water 56.0 °C Auto > Change room temperature > Change room temperature Fig. 4.
Operation 4 Hot water Heating circuit (HC1) Changing parameters in the basic display Parameter Meaning Room target temperature The heating is controlled with reference to the modified room target temperature for a specific period that depends on the operating mode selected, also see Section 4.4. Operating mode Auto(matic) The control of the heating unit is carried out in accordance with the preset room set target temperature, the time programmes and other parameters such as e.g. night set back temp.
4 Operation This is how to do it: Turn the left-hand dial. The operating mode is highlighted. After a delay of one second, you can select the operating mode. Continue to turn the left-hand dial until the desired operating mode is displayed. The selected operating mode is accepted after a delay of two seconds. The display changes from inverse back to normal. Th. 12.01.06 11:46 20.5 °C Auto > change room temperature Fig. 4.
Operation 4 Room temperature 4.5 Operation level for the operator, operation level for the expert technician The VRT 392f is equipped with two operation levels. Each level contains several screens in which the various parameters can be displayed, adjusted or changed. 25 ° 20 ° – Operation level for the operator Used to display and set/change the basic parameters. The setting/changing of parameters can be carried out by the user without any special previous knowledge and during normal operation.
4 Operation Screen 1 Title screen Adjustable operating values (only display = A) Remarks Basic data Date Weekday Time of the day Select Day, Month and Year separately; Select Hour and Minutes separately Unit Min. value Max. value Summer/Winter changeover Default value Auto, Off Off Weekday/Block Select a weekday or a block of days (e. g.
Operation 4 4.7 Editing screens (examples) 4.7.1 Entering time programmes (example for heating) Using the time programmes you can allocate up to three time windows per weekday, or block of days (e.g. Mo - Fr). In these time windows, the heating system maintains the room temperature that you have selected, the so-called comfort temperature. Outside the time windows, the room temperature is set back. The set-back temperature can also be changed.
4 Operation Enter the room temperature as follows: h Note The same procedure as shown in the example for heating circuit applies when inputting the time programme for hot water generation or for a circulation pump. A comfort temperature does not need to be entered for hot water generation and the circulation pump. 4.7.2 Programming holiday periods For a longer period of time when you are not at home, you can define a lower room temperature. This will save heating energy.
Operation 4 4.7.4 Entering the parameters for hot water generation If the hot water for your home is generated by the appliance the target temperature can be entered via the VRT 392f. Click the right-hand dial. The character is inversely displayed. Turn the right-hand dial to select the correct letter or number. Click the right-hand dial. Turn the left-hand dial until you reach Screen "Hot water parameters". 10 The cursor is positioned in front of the value for the target temperature.
5 Status and error messages 5 Status and error messages Status and error messages are displayed in the second row of the field for basic data. This is how to do it: Pull the controller (1) off the wall socket (2). This can be done by pushing a screwdriver into the two retaining straps (see Fig. 5.1 arrows). Status messages 1 Holiday Within a set holiday time period the heating is controlled to the room set target temperature for this period.
Status and error messages 5 h Note Ensure correct polarity of the batteries (see Fig. 5.2). Always change all batteries at the same time. Only use the following battery type: Alkaline AA/LR6 Battery 1.5 V. Do not use rechargeable batteries. Depending on use, the batteries last between approx. 1 and 1.5 years. Carefully push the controller onto the wall socket (2) until it snaps into place. The display remains dark The display remains dark although you turn or click one of the dials.
For the expert technician Installation instructions VRT 392f Room thermostat VRT 392f Contents 1 1.1 1.2 1.3 Notes on the documentation .........................2 Storage of the documents ....................................2 Symbols used ...........................................................2 Validity of the instructions ...................................2 2 2.1 2.2 2.3 Description of the device ............................... 3 Identification plate ...........................................
1 Notes on the documentation 1 Notes on the documentation The following notes are intended to help you throughout the entire documentation. Further documents apply in combination with this installation manual. We accept no liability for any damage caused by failure to observe these instructions. Other applicable documents – Operating manual for the Vaillant room thermostat VRT 392f – The operating and installation instructions for your heating system – All instructions for the accessories 1.
Description of the device 2 2 Description of the device The VRT 392f is a programmable room thermostat for the heating and control of hot water generation in conjunction with a Vaillant appliance (eBUS-compatible).
3 Safety instructions and regulations 3 Safety instructions and regulations The VRT 392f must be installed by a recognised expert technician company that is responsible for ensuring that existing standards and regulations are observed. We will not accept liability for damage arising from nonobservance of this manual. 3.1 Safety instructions e Danger! Voltage carrying connections! When working in the control cabinet of the appliance there is a danger to life by electric shock.
Assembly 4 4 Assembly The VRT 392f must be installed in the living area against a wall. The connection with the appliance is made using a radio link. 4.1 Scope of delivery Using Table 4.1, check the scope of delivery. Pos. number Component 1 1 Room thermostat VRT 392f 2 1 Fixing equipment 3 1 Radio receiver unit 4 1 Wall socket for radio receiver unit 5 1 Battery set (4x AA) 6 1 Operating and Installation instructions Table 4.1 Scope of delivery VRT 392f 4.
4 Assembly 4.4.1 Mounting the radio receiver unit on the wall h Note It is only necessary to mount the radio receiver unit on the wall if the position of the radio receiver unit needs to be changed in order to establish reliable radio communication with the controller. 4.5 Mounting the control on the wall During initial operation of the appliance in the chosen installation location check that the radio signal path is not adversely affected by electrical devices or building components.
Assembly 4 Installation 5 5.1 Electrical installation for the wall-mounted wireless receiver unit h Note It is only necessary to mount the radio receiver unit on the wall if a more suitable position for the radio receiver unit needs to be found in order to ensure reliable radio communication with the controller. The power supply to the appliance must be disconnected and prevented from being unintentionally switched back on. Fig. 4.
6 Initial commissioning 6 Initial commissioning Initial condition: The controller calorMATIC 392f and the radio receiver unit are installed correctly. The appliance is switched on and ready for operation. The quality of the wireless data communication for outdoor sensors and controllers is represented by a number between 0 and 10.
Initial commissioning 6 If you wish to leave the installation assistant: Code layer enable Turn the left-hand dial in a clockwise direction to navigate to screen A6. Confirm the end of the installation with "Yes". After the installation is concluded, you will automatically reach the simplified basic display. 6.2 Operation level for expert technician Specific operating data can be displayed and adjusted/changed at the expert technician operation level.
6 Initial commissioning Screen Title screen Adjustable operating values (only display = A) Remarks Unit Min. value Max.
Initial commissioning 6 Factory customer service, manufacturer's guarantee 7 Recycling and disposal 8 6.4 Handover to the operator The operator of the VRT 392f must receive instruction on handling and functions of the controller. Hand the instruction manuals and documents for the appliance over to the operator for safe keeping. Inform the operator what the article number is. Point out to the operator that the manual must be kept near to the VRT 392f.
9 Technical data 9 Technical data Parameter VRT 392f Operating voltage Umax 4x1.5 V (AA) Service life of battery (alkaline) approx. 1.5 years Level of protection IP 20 Protection class III Maximum permissible ambient temperature 50 °C Transmission frequency 868 MHZ Transmitting power < 10 mW Range: in free field > 100 m in building approx. 25 m Height mm 97 Width mm 146 Depth mm 45 Table 9.1 Technical data VRT 392f Parameter Radio receiver unit Operating voltage Umax max.
Appendix Glossary Glossary Set-back temperature The set-back temperature is the reduced interior temperature maintained by your heating system outside of the programmed time window. Operation level for operator Used to display and set/change the basic parameters. The setting/changing of parameters can be carried out by the user without any special previous knowledge and during normal operation.