Operation Manual

Installation instructions VRT 392f 0020044239_0110
Screen Title
screen
Adjustable
operating values
(only display = A)
Remarks Unit Min.
value
Max.
value
Increment Default
value
C1 HC1
In
formation
Target flow
temperature (A)
Flow temperature
target value
°C 1
C4 Ho
t water
information
Current target hot
water (A)
Target temperature of
hot water in cylinder
°C 1
Cylinder sensor 1 (A) Actual temperature of
hot water in cylinder
°C 1
Cir
culation pump
status (A)
On, Off
C9 HC1
p
arameters
Set-back
temperature
A set-back temperature
can be specified for the
periods between the
time windows.
°C 5 30 1 15
Control strategy Determines the type of
room temperature
control
T
wo point represents
on/off control;
Similar to a modulating
control.
Two-point,
analogue
Two-point
Route matching For optimum matching
to the size of the room
or radiator
arrangement.
(P
ositive values: slower
switching response of
controller;
negative values: faster
switching response of
controller).
-5 +5 1 0
C16 Ho
t water
parameters
Legionella protect
day
Day or block of days;
The cylinder is heated
up to 70°C for an hour
OFF, MO, TU,
WE, TH, FR,
SA, SU,
MO-SU
OFF
Start time of
Legionella
protection
0:00 24:00 0:10 4:00
C24 Service T
elephone number Input of telephone
number for the
purposes of servicing
Changing the code
number
0000 9999 e
ach 1 1000
Maintenance date Day/Month/Year
adjustable
C25 Tools Room temperature
correction
Adjustment of room
temperature sensor
R -
3 3 0,5 0
Display contrast 0 15 1 6
C2
6 Software versions Software version
per module (A)
Display of version
number
T
able 6.2 Screens in the expert technician operation level
10