Local Serial Line
Observation and alarm messages can be sent over local RS232 and
RS485 lines. The following line parameters are fixed in AWS for both
COM0 (RS232) and Data Out (RS485):
Table 32 Serial Line Parameters
Parameter Value
Speed 9600 bps
Data bits 8
Stop bits 1
Parity None
Use the following parameters to control which messages are sent to local
serial lines (see Table 26 on page 121 and Table 27 on page 123):
- csv_to_com0
- csv_to_local
- table_to_com0
- table_to_local
- sms_to_com0
- sms_to_local
- alrmet_to_local
- alrmet_to_com0
- alrtech_to_local
- alrtech_to_com0
Set interval of the selected observation message type by (see Table 25 on
page 120):
- csv_interval
- sm
s_interval
- table_interval