Owner manual

Chapter 5 __________________________________________ Software Configuration and Operation
VAISALA ______________________________________________________________________ 149
Changing Sensor Configuration
If standard AWS330 sensors are added to or existing sensors are removed
from the configuration, sensor management parameters should be
changed accordingly.
The following parameters are used to control sensor configuration:
1012-169
Figure 88 Changing Sensor Configuration
Table 40 Sensor Selection Parameters
Set Name Parameter Name Sensor
General settings HMP155 Air temperature and relative humidity probe
HMP155
General settings PMT16A Barometric pressure sensor BARO-1
General settings QMT110_1 Soil/water temperature sensor QMT110
General settings QMT110_2 Soil/water temperature sensor QMT110
General settings RG13 Rain gauge RG13
General settings CMP6
(1
Global radiation sensor CMP6
General settings IRU_9429 Snow height sensor IRU-9429
General settings WIND Wind sensor
General settings WA15 Wind sensor type
0 = Ultrasonic WMT700 series
1 = Mechanical WAV15/WAA15
(1
Global radiation sensor CMP6 has unique sensitivity factor that needs
to be entered to the AWS330 system as described in section Replacing
CMP6 on page 184.
Settings: 0 = Sensor/option is not selected, 1= Sensor/option is selected.