Station name: AWS330
Date: 2010.11.26 10:29:13
MAWS:
Internal temperature: 17.7
DC supply voltage: 13.5
Sensors:
Instant Average Status
Temperature: 0.3 0.3 0
Air pressure: 1000.0 1000.0 0
Relative humidity: 64 64 0
Wind direction: 68 77 0
Wind speed: 3.8 3.4 0
Precipitation: 0.0 0 0
Snow depth: 1275 12.5 0
Solar radiation: 630 630 0
Soil temperature1: -0.7 -0.2 0
Soil temperature2: -3.1 -2.7 0
SMS Message
Note: The actual message does not contain linefeeds.
(S:AWS330;D101207;T:150400;TA:-22.2;RH:20; DP:-30.5;PA:1002.7;
PR:0.8;WD:230;WS:2.5;SR:777;TS1:-10.2;TS2:-11.6;SH:120)
Alarm Messages
(S:AWS330;D:101129;T:090800;ALARM:Internal temperature;TINT:66)
(S:AWS330;D:101129;T:090800;ALARM:Temperature;TAAVG1M:-3.0)
(S:AWS330;D:101129;T:090700;ALARM:Supply voltage low;EXTDC:9.5)
(S:AWS330;D:101129;T:091500;ALARM:Windspeed;WSMAX10M:30.0)
(S:AWS330;D:101129;T:100100;ALARM:Precipitation;PRSUM1H:0.0)