Owner manual

User's Guide ______________________________________________________________________
28 __________________________________________________________________ M211296EN-B
Table
Table message is a message in readable format with instant values and
sensor status values.
The following values are displayed in the table message:
Table 13 Table Message Values
Row Label/Column Instant Average Status
(1
Station name Station name
Date Date time UTC
Internal temperature [°C] Logger internal
temperature
DC supply voltage [V] Logger DC supply
voltage
Temperature [°C] HMP155 air
temperature
1 min average
temperature
HMP155 air
temperature status
Relative humidity [%] HMP155 relative
humidity
1 min average
relative
humidity
HMP155 relative
humidity status
Wind direction [deg] 3 sec average
wind direction
10 min average
wind direction
WMT700 status
Not available for
WAV15 (99)
Wind speed [m/s] 3 sec average
wind direction
10 min average
wind speed
WMT700 status
Not available for
WAA15 (99)
Precipitation [mm],[mm/h] 1 min cumulative
precipitation from
rain gauge
Precipitation
intensity
calculated over
10 minutes
Rain gauge status
Snow depth [mm],[cm] Sensor IRU 9429
reading
Snow height IRU 9429 status
Soil temperature 1 [°C] QMT102 soil
temperature
1 min average
soil
temperature
QMT102 status
Soil temperature 2 [°C] QMT102 soil
temperature
1 min average
soil
temperature
QMT102 status
(1
See Appendix D, Sensor Status Values, on page 293.
Missing observation values are replaced with one or more slash '/'
characters.
See example Table Message on page 290.