User`s guide

Technical Reference_________________________________________________________________
68 ___________________________________________________________________ M210511EN-A
2. Status, indicates the internal status of the MAWS interface
for USA-1, and the possible values. See below for value
descriptions:
Value Description
0 The sensor is working properly (OK)
1 Not measured yet
2 Interface not initialized (no message received
after startup)
3 Communication timeout
4 Unknown data received
6 Sensor communication paused because pass-
through service connection opened using
MAWS (or no message received after startup
when Ignore frames option is selected)
30 Measurement/sensor has been manually
disabled
3. Temp, temperature in Celsius degrees
4. Xcomp, x-component of wind in unit of m/s
5. Ycomp, y-component of wind in unit of m/s
6. Zcomp, z-component of wind in unit of m/s
Vaisala Wind Vane
Installing Wind Vane WAV151
Note that before you can install the mechanical Vaisala Wind Vane
WAV151, you have to install the Digital I/O Module QMI108 and
connect it to the logger.