USER'S GUIDE Digital Barometers with Analog Output PTB210 Series M210670EN-B
PUBLISHED BY Vaisala Oyj P.O. Box 26 FIN-00421 Helsinki Finland Phone (int.): +358 9 8949 1 Fax: +358 9 8949 2227 Visit our Internet pages at http://www.vaisala.com/ © Vaisala 2006 No part of this manual may be reproduced in any form or by any means, electronic or mechanical (including photocopying), nor may its contents be communicated to a third party without prior written permission of the copyright holder. The contents are subject to change without prior notice.
_________________________________________________________________________________ Table of Contents CHAPTER 1 GENERAL INFORMATION ............................................................................ 3 Safety......................................................................................... 3 Feedback............................................................................... 3 Recycling .................................................................................. 4 Trademarks .......
User's Guide _______________________________________________________________________ List of Figures Figure 1 Figure 2 Figure 3 Figure 4 PTB210 and the Standard Accessories .....................................7 The BAROCAP® Pressure Sensor ............................................8 Different Mounting Options of the PTB210.................................9 Recommended Cable Position .................................................
Chapter 1 _________________________________________________________ General Information CHAPTER 1 GENERAL INFORMATION Safety Throughout the manual, important safety considerations are highlighted as follows: WARNING Warning alerts you to a serious hazard. If you do not read and follow instructions very carefully at this point, there is a risk of injury or even death. CAUTION Caution warns you of a potential hazard.
User's Guide _______________________________________________________________________ Recycling Recycle all applicable material. Dispose of batteries and the unit according to statutory regulations. Do not dispose of with regular household refuse. Trademarks BAROCAP® is a registered trademark of Vaisala. License Agreement All rights to any software are held by Vaisala or third parties.
Chapter 1 _________________________________________________________ General Information Warranty Vaisala hereby represents and warrants all Products manufactured by Vaisala and sold hereunder to be free from defects in workmanship or material during a period of twelve (12) months from the date of delivery save for products for which a special warranty is given.
User's Guide _______________________________________________________________________ This page intentionally left blank.
Chapter 2 _________________________________________________________ Product Description CHAPTER 2 PRODUCT DESCRIPTION The PTB210 series digital barometers are designed for various pressure ranges. The barometers with an analog output are available with different scalings between 500 ... 1100 hPa for 0 ... 5V or 0 ... 2.5V. The PTB210 series barometers are also available with a digital output. The PTB210 series barometers offer an excellent solution for outdoor installations.
User's Guide _______________________________________________________________________ The PTB210 barometers incorporate the BAROCAP® silicon capacitive absolute pressure sensor developed by Vaisala. The sensor features excellent hysteresis and repeatability characteristics and has an outstanding temperature and long-term stability.
Chapter 3 ________________________________________________________________ Installation CHAPTER 3 INSTALLATION Mounting Due to the compact design of the PTB210, all you need to do is to mount the instrument, and to connect the wires. Use one of the following three mounting options. - Remove the pressure fitting, and place the barometer on a desired structure. Then, fix it with the slot headed screws, the O-ring sealing the attachment (A).
User's Guide _______________________________________________________________________ NOTE Check that the cable is not taken upwards from the barometer. This is to prevent water flowing along the cable, and gathering close to the feed-through. Figure 4 Recommended Cable Position The IP65-classified housing enables the barometer to be mounted outdoors without any additional protection. However, please take care that rainwater cannot plug the open pressure fitting.
Chapter 3 ________________________________________________________________ Installation Connections Connect the wires of the PTB210 barometer according to Table 1. Use the pink wire for the supply voltage (8 ... 18 VDC), and the blue wire for grounding. The output signal is read from the white wire and grounded with the brown wire. The gray and green wires are used to connect the barometer to PC when using the calibration Wizard software, or to Vaisala PMI20 digital barometer display.
User's Guide _______________________________________________________________________ This page intentionally left blank.
Chapter 4 ___________________________________________________ Calibration and Adjustment CHAPTER 4 CALIBRATION AND ADJUSTMENT The PTB210 series barometers can be fine adjusted and calibrated against pressure standards that have high accuracy and stability as well as known traceability to international standards. By comparing the output to a reference, the user can define the corrections required for readjustment. NOTE Calibration is considered not to involve any adjustments.
User's Guide _______________________________________________________________________ Operation •To start the Wizard program in NT: 1. Double-click the My Computer icon. 2. Double-click the drive that contains the file. 3. To start the program, double-click the WIZARD.EXE-file. OR •To start a program by using the Run command in NT 1. Click Start, and then click Run. 2. In the Open box, type the location and name of the program you want to start.
Chapter 4 ___________________________________________________ Calibration and Adjustment 3. Give reference pressure values and the corresponding corrections. Calculate the corrections according to the equations below. NOTE Because the lower end of voltage output is not exactly 0 V, use as lower calibration point a value approximately 40 mV above the lower end limit. Thus with scale 600…1060 hPa and 0…5V output the lowest calibration point will be 604 hPa.
User's Guide _______________________________________________________________________ Reference Correction 4. To save the new corrections, click the Write PTB210-button.
Chapter 4 ___________________________________________________ Calibration and Adjustment 5. The program then asks a password. As default, no password exists. Just click OK. The password can be used to prevent saving of any new corrections without entering it. To give a password, click the Change-button. 6. Enter a new password and confirm by re-entering it. NOTE Remember to set the MPC corrections on after given them.
User's Guide _______________________________________________________________________ This page intentionally left blank.
Chapter 5 _____________________________________________________________ Technical Data CHAPTER 5 TECHNICAL DATA Technical Specifications Operating Range Pressure range (order specified) Operating temperature range Humidity range 500 ... 1100 hPa 800 ... 1060 hPa 600 ... 1060 hPa 900 ... 1100 hPa -40 ... +60°C non condensing Accuracy Non linearity* Hysteresis* Repeatability* Calibration uncertainty** Total accuracy (20°C)*** Temperature dependence (-40 ... +60°C)**** Total accuracy*** (-40 ...
User's Guide _______________________________________________________________________ Long term stability ± 0.10 hPa/year * Defined as the ±2 standard deviation limits of end-point non-linearity, hysteresis error or repeatability error. ** Defined as ±2 standard deviation limits of inaccuracy of the working standard including traceability to NIST.
Chapter 5 _____________________________________________________________ Technical Data Electromagnetic Compatibility Electromagnetic compatability EN61326-1:1997+ Am1:1998 + Am2:2001 Generic environment [CISPR16/22 class B, EN 610004-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6] VAISALA________________________________________________________________________ 21
User's Guide _______________________________________________________________________ 122.5 (4.82) 32 (1.26) 16 (0.63) 120 (4.72) Dimensions in mm (inches) 50 (1.
Chapter 5 _____________________________________________________________ Technical Data 5x45° (0.2x45°) 50.40 (1.98) 14.20 (0.56) 4.50 (0.18) 10 (0.39) 2 (0.08) 19 (0.75) 30 (1.81) M3 40 (1.57) 37 (1.46) 60 (2.36) 14x45° (0.55x45°) M3 ø15 (0.59) 50 (1.97) 21 (0.
www.vaisala.