Measurement Enable or Disable
You can manually enable or disable all measurement inputs and
sensors. You can use this feature for example to:
- Change remotely the readings of a faulty sensor to be flagged as
invalid.
- Mark all sensor readings invalid during the maintenance operation.
Use the following commands in the service connection to change the
flagging:
enable <Measurement Name>
disable <Measurement Name>
Examples:
>\ disable RHMeasQMH101_1
>\ disable TAMeasQMH101_1
>\ disable WMS302_1
>\ enable PWD11_1
Upon successful completion of the commands MAWS return:
Successfully disabled
or
Successfully enabled
Any other returned values indicate an error.
where
enable = Enables the measurement inputs or sensors.
disable = Disables the measurement inputs or sensors.
Measurement Name = The measurement name from the
Configuration view of MAWS Lizard.
NOTE
For the sensors, that use more than one input channel, you need to enter
separate commands for each measurement. For example, you need to
control separately the TA and RH measurements of the QMH101
sensor.