Manual
TECHNICAL REFERENCE___________________________________________________________ 
30 __________________________________________________________________ M211097EN-C 
Table 8  Analog Output Connections 
WMT700 
Connector 
Pin 
WMT700 Signal 
Description 
Voltage Output WS425 Connector Pin, 
Wire Color 
Voltage  15: Violet (connect pin 14 
to ground) 
Current not available 
13 Analog Output 
AOUT1, Wind 
Speed 
Frequency 14, Pink 
Voltage 13, Grey 
Current not available 
2 Analog Output 
AOUT2, Wind 
Direction 
Potentiometer 13, Grey 
17 Reference Input 
for AOUT2 
Potentiometer 12, White 
12 Analog Output 
Ground 
All modes  1, Black (common with 
supply ground) 
Powering 
WMT700 is designed to operate with the same supply voltages as WS425 
and no connection changes are necessary. The power consumption 
depends on the selected heating options. WMT700 with Heated 
Transducers can be used to replace similar WS425 models. When 
upgrading from WS425 to WMT700 with Heated Transducers and Arms, 
more capacity is required from the power supply unit. 
For information on power supply requirements of each WMT700 product 
type, see Table 9 below. 
For more information on powering, see Vaisala WINDCAP
® 
Ultrasonic 
Wind Sensor Series WMT700 User's Guide. 
Table 9  Heating Power Supply Requirements for WMT700 
Series 
Heating Option  Heating Voltage 
Required Heating 
Power Supply 
None -  - 
Transducers  24/36 VDC  40 W 
Transducers and arms  24 VDC  200 W 