Manual
TECHNICAL REFERENCE___________________________________________________________ 
36 __________________________________________________________________ M211097EN-C 
0212-039 
Figure 10  Wind Speed Frequency Analog Output with WS425 
Cable and Adapter Cable for Analog Frequency 
Output 
Voltage 
When voltage is selected as the wind speed analog output, the output 
from WMT700 varies linearly from 0 VDC at 0 miles per hour to 1 VDC 
at 125 miles per hour or 100 mV/m/s. In SI units, the voltage varies 
linearly from 0 VDC at 0 meters per second to 1 VDC at 55.88 meters 
per second. 
Figure 11 on page 37 shows the voltage output when an adapter cable for 
voltage output and a WS425 cable are used. With WMT700, the wind 
speed signal appears at pin 14 (pink). The pink wire must be connected to 
V read channel, and the violet wire must be connected to the ground. 