Manual
TECHNICAL REFERENCE___________________________________________________________ 
38 __________________________________________________________________ M211097EN-C 
0212-040 
Figure 12  Wind Direction Voltage Output with WS425 Cable and 
Adapter Cable 
Limitations for Output Signals 
You can specify the minimum and maximum values for analog output 
with the configuration parameters. The output is fixed to the specified 
values, and the unit depends on the selected analog output mode. 
Example 
To limit the output 1 in voltage mode to a range of 0.1 … 5 V, set the 
analog output minimum value to 0.1 and the analog output maximum 
value to 5. Enter the following commands: 
S aout1minv,0.1 
S aout1maxv,5 
For information on the parameters, refer to Vaisala WINDCAP
®
Ultrasonic Wind Sensor Series WMT700 User's Guide. 