Chapter 5 ______________________________ Operating WMT700 with WS425 and SDI-12 profiles 
VAISALA _______________________________________________________________________ 43 
For the correct settings for SDI-12 profile, see section SDI-12 on 
page 60. 
7. Click Apply and OK. 
8. On the Settings tab, click ASCII setup. Select ASCII sending - 
Send line ends with line feed (optional). Click OK and close the 
New Connection Properties window. 
9. On the View menu, click Font. In the Font list, select Terminal. 
10. From the Call menu, click Call. Enter a name and select an icon 
for the connection. Click OK. 
11.  Switch the sensor power supply on. 
The following information is displayed: 
wmt700 v.<version number> 
12.  Wait for 4 seconds. WMT700 enters measurement mode 
automatically. 
13.  To test the connection, enter configuration mode with the following 
command. 
$0OPEN<CR><LF> 
14.  Use the following command to return to measurement mode: 
CLOSE<CR><LF> 
You can now start operating WMT700. However, WMT700 does 
not send data messages automatically unless configured to do so. 
For information on operating commands and data messages, see the 
profile-specific section in Vaisala WINDCAP
®
 Ultrasonic Wind 
Sensor Series WMT700 User's Guide. 
NOTE 
In configuration mode, you can use any of the following end-of-line 
character combinations: <
CR><LF>, <CR>, or <LF>. 