Table 11  Configurable Parameters for WS425 F/G ASOS Profile 
Parameter Default 
Value 
Profile-specific Allowed 
Values 
Description 
autoSend  0  0 = automatic messages 
disabled 
Automatic data message 
number. Selects the data 
message format for automatic 
messages. 
com1_protocol 
com2_protocol 
(depending on the port 
used for operating 
WMT700) 
0  2 = WS425 F/G ASOS 
Profile for serial ports COM1 and 
COM2. 
wndAvg  1  0.25 … 3600 
Resolution: 0.25 
Averaging time for wind 
measurement in seconds. 
wndGustTime  3  0.25 … 3600 
Resolution: 0.25 
Averaging time for wind minimum 
and maximum in seconds. 
wndOrientation  0  0 = array facing up 
1 = array facing down 
Orientation of the array of 
WMT700. 
wndUnit  0  0 = meters per second (m/s) 
1 = miles per hour (mph) 
2 = kilometers per hour (km/h) 
3 = knots (knot) 
Wind speed unit. 
wndVector  1  0 = scalar averaging 
Wind averaging method. 
To start continuous measurement, use the START command. You can 
stop the measurement with the STOP command. For instructions, refer to 
Vaisala WINDCAP
®
 Ultrasonic Wind Sensor Series WMT700 User's 
Guide. 
WS425 F/G ASOS Commands 
WMT700 responds to each command with a fixed-length message. In 
each of the command descriptions below, <CR> is an ASCII carriage 
return control character and <LF> is an ASCII line feed control 
character. 
NOTE 
When the WS425 F/G ASOS profile is selected, WMT700 only responds 
to upper case characters. 
Table 12 below lists the available commands for operating WMT700 
with the WS425 F/G ASOS profile. 
Table 12  List of WS425 F/G ASOS Commands 
Command  Description 
WA  Requests average wind speed and direction message. 
WS  Requests the verbose Built-In Test (BIT) results. 