Manual
Chapter 5 ______________________________ Operating WMT700 with WS425 and SDI-12 profiles 
VAISALA _______________________________________________________________________ 59 
WS425 A/B WAT11 Commands 
When the WS425 A/B WAT11 profile is selected, you can poll data 
using the following command: 
<esc><id> 
where 
<esc>  =  Escape character ASCII 27H 
<id>  =  The WMT700 ID, for example, A 
The response is the following: 
<stx><id><spd><dir> 
where 
<stx>  =  Start of text character (1 digit) 
<id>  =  The WMT700 identification character, for example, A (one 
digit). 
<spd>  =  Wind speed (in meters per second) multiplied by 10. For 
example, 045 is 4.5 meters per second (three digits). 
<dir>  =  Wind direction with two octal numbers for 6-bit binary data, 
for example, 73 corresponds to (7*8+3)/64*360 = 332 
degrees. 
Missing Readings 
The WS425 A/B WAT11 message reports missing data as slashes (/////). 