Manual
TECHNICAL REFERENCE___________________________________________________________ 
68 __________________________________________________________________ M211097EN-C 
aM! — Start Measurement 
This command starts measurement. WMT700 does not return 
measurement data after this command. It sends a response that indicates 
when the measurement result can be retrieved using the aD0! command 
and the number of parameters. 
aM! 
where 
a  =  The single-digit WMT700 address that corresponds to 
the first character of the address value. 
M  =  The start measurement command. 
!  =  Terminates the command. 
The response is the following: 
atttn<CR><LF> 
where 
a  =  The single-digit WMT700 address that corresponds to 
the first character of the address value. 
ttt  =  The period of time, in seconds, after which WMT700 
has the measurement ready. 
n  =  The number of measurement values WMT700 
calculates and returns as a response to one or more 
subsequent aD0! commands. 
<CR><LF>  =  Terminates the response. 
Example of the command and response: 
1M! 
10025<CR><LF> 
Interpretation of the example message: 
-  Time after which the measurement is ready: 2 second 
-  Number of returned measurement values: 5 
To fetch the measurement results, use the aD0! command. 