Manual
TECHNICAL REFERENCE___________________________________________________________ 
76 __________________________________________________________________ M211097EN-C 
Configuration Mode/ 
Measurement Mode 
and Profile 
Command  Description 
Further Information
1
Measurement mode 
WMT700 profile 
OPEN  Switches the serial port to 
configuration mode. 
User's Guide 
Measurement mode 
WMT700 profile 
POLL  Fetches data from WMT700.  User's Guide 
Measurement mode 
WMT700 profile 
SLEEP  Switches WMT700 from normal 
operating mode to low-power mode.
User's Guide 
Measurement Mode 
MES12 profile 
@a M 12  Polls data from WMT700 in the 
MES12 data message format. 
User's Guide 
Measurement mode 
WS425 ASOS F/G 
profile 
WA  Requests average wind speed and 
direction message. 
Technical Reference 
Measurement mode 
WS425 ASOS F/G 
profile 
WS  Requests the verbose Built-In Test 
(BIT) results. 
Technical Reference 
Measurement mode 
WS425 A/B NMEA 
Extended profile 
$WIP  Polls data from WMT700.  Technical Reference 
Measurement mode 
WS425 A/B ASCII profile 
I  Requests identification information 
for WMT700. 
Technical Reference 
Measurement mode 
WS425 A/B ASCII profile 
Wx  Starts measurement based on 
averaging time and fetches the 
data. 
Technical Reference 
Measurement mode 
WS425 A/B WAT11 
profile 
<esc><id>  Polls data from WMT700.  Technical Reference 
Measurement mode 
SDI-12 profile 
?!  Queries WMT700 for its address.  Technical Reference 
Measurement mode 
SDI-12 profile 
a!  Ensures that WMT700 is 
responding. 
Technical Reference 
Measurement mode 
SDI-12 profile 
aI!  Queries WMT700 for its SDI-12 
compatibility level, model number, 
and firmware version number. 
Technical Reference 
Measurement mode 
SDI-12 profile 
aAb!  Changes WMT700 address.  Technical Reference 
Measurement mode 
SDI-12 profile 
aC!  Starts concurrent measurement.  Technical Reference 
Measurement mode 
SDI-12 profile 
aCC!  Starts concurrent measurement. 
CRC is included in the response. 
Technical Reference 
Measurement mode 
SDI-12 profile 
aD0!  Fetches instant data from WMT700. Technical Reference 
Measurement mode 
SDI-12 profile 
aM!  Starts measurement.  Technical Reference 
Measurement mode 
SDI-12 profile 
aMC!  Starts measurement. 
CRC is included in the response. 
Technical Reference 
Measurement mode 
SDI-12 profile 
aV!  Starts verification.  Technical Reference 