Installation guide
   SV-EMS-220/221 Installation and Configuration 
SkyView System Installation Guide - Revision R    7-3 
Physical Installation 
The diagram below shows the mounting dimensions of the EMS module with electronic 
connections. 
Figure 27–SV-EMS-220/221 Mounting Dimensions with Electronic Connections 
Dynon does not include mounting hardware for use with the SV-EMS-220/221. The mounting 
tabs on each side of the module have holes sized for #10 fasteners, but it is up to the installer 
to decide how the EMS will be secured to the aircraft. Use of ferrous fasteners in this location is 
acceptable as the EMS is not adversely affected by small magnetic fields. Dynon recommends 
button head style AN hardware as spacing between the holes in the tabs and the body of the 
enclosure will limit what style tool can be used to tighten certain fasteners. If you will be 
installing dual SV-EMS-220/221s, it is acceptable to stack the two units. Follow recommended 
torque practices when tightening the mounting hardware. Do not rivet the SV-EMS-220/221 to 
the aircraft as this will hinder future removal if necessary. 