Installation guide
   SV-EMS-220/221 Installation and Configuration 
SkyView System Installation Guide - Revision R    7-5 
Dynon Part Number 
Description 
Mates with… 
100399-000 
EMS 37-pin Main Sensor Harness 
SV-EMS-220/221 Male D37 
100399-001 
EMS EGT/CHT 4-cylinder 25-pin 
Thermocouple Wire Harness 
SV-EMS-220/221 Female D25 
100399-002 
EMS EGT/CHT 6-cylinder 25-pin 
Thermocouple Wire Harness 
SV-EMS-220/221 Female D25 
100399-004 
EMS EGT 2-cylinder 25-pin 
Thermocouple Wire Harness 
SV-EMS-220/221 Female D25 
Table 12–EMS Wire Harnesses 
A typical SV-EMS-220 installation will utilize one EMS 37-pin Main Sensor Harness and one of 
thermocouple wire harness. A typical SV-EMS-221 installation does not utilize a thermocouple 
harness. Choose a thermocouple wire harness based on the number of EGTs and/or CHTs that 
need to be monitored. 
The EMS 37-pin Main Sensor Harness includes a 9-pin connector that is wired to 
pins 11 (Orange wire), 12 (Yellow wire), and 30 (Black wire). This connector is 
used for other Dynon products, but is not used in SkyView installations. Thus, 
the 9-pin connector should be removed to use these wires for connecting 
sensors to the SV-EMS-220. Remove the connector by cutting the three wires 
close to the 9-pin connector. 
The EMS 37-pin Main Sensor Harness (Dynon P/N 100399-000) may be wired 
with blue and green wires on pins 36 and 37, respectively. If you are going to use 
pins 36 and 37 for a thermocouple input such as a CHT or EGT (this is not 
possible on the SV-EMS-221 that is used with the Rotax 912 iS, as these wires are 
reserved for CAN communications), the blue and green wires should be removed 
and replaced with the appropriate type of thermocouple wire for thermocouple 
functionality on pins 36 and 37. If you are not going to use these pins for a 
thermocouple input, the blue and green wires do not need to be removed. 
All of the ground wires on the SV-EMS-220/221 D37 are interchangeable, and can 
be used for any sensor that requires grounding. Additionally, one of these wires 
needs to be grounded to the aircraft locally to provide a good ground reference 
for the engine sensors. We suggest using the black ground wire connected to D37 
pin 3 for this purpose. 
Sensor and Transducer Compatibility Key 
This section is primarily intended for users with installations that are not 
supported in or significantly deviate from the preconfigured installation resources 
available from Dynon. Reference Example Engine Sensor and Transducer 
Installations Section for installations which have downloadable preconfigured 
installation resources. 