Installation guide
SV-EMS-220/221 Installation and Configuration    
7-6    SkyView System Installation Guide - Revision R 
This section explains how to use Table 13–Sensor and Transducer Compatibility Level Key. 
There are three compatibility designations: A, B, and C. These designations are explained in the 
following paragraphs. 
Sensor and transducer compatibility level A denotes that an SV-EMS-220/221 D37 pin labeled 
as “A” in Table 14 can be configured to support the vast majority of sensors and transducers 
used in aircraft installations, which are primarily resistive in nature. Sensors and transducers 
include contacts, fuel level, fluid pressure, fluid temperature, temperature, and position 
potentiometers. For example, SV-EMS-220/221 D37 pin 4 can be configured to read a resistive 
oil temperature sensor. 
Sensor and transducer compatibility level B denotes that an SV-EMS-220/221 D37 pin labeled as 
“B” in Table 14 can be configured to support every sensor and transducer listed for “A” while 
also being compatible with 4 to 20 mA constant current source output sensors that are 
supported (currently only the Rotax P/N 956413 Honeywell and Rotax P/N 456180 oil pressure 
sensors). 
Sensor and transducer compatibility level C denotes that an SV-EMS-220/221 D37 pin labeled as 
“C” in Table 14 can be configured to support every transducer and sensor listed for “A” while 
also being compatible with senders that employ active voltage output hardware including 
Dynon’s Capacitance-to-Voltage Converter. 
If an SV-EMS-220/221 pin’s sensor config space is blank in Table 14, that means that pin has 
fixed functionality. This functionality is described under the Function column in the table. 
Sensor and Transducer 
Compatibility Level 
Example sensors and transducers 
A 
Contacts 
Fuel Level (resistive) 
0-150 PSI Fluid Pressure (100411-002) 
1/8”-27 NPT Fluid Temperature (100409-000) 
5/8”-18 NPT Fluid Temp (100409-001) 
0-30 PSI Fluid Pressure (100411-000) 
0-80 PSI Fluid Pressure (100411-001) 
Jabiru Oil Temperature 
Jabiru Oil Pressure 
Dynon 2-Wire OAT Probe (100433-003) 
Dynon 2-wire Carburetor Temperature (100468-000) 
Rotax CHT or Oil Temperature (801-10-1) 
Flap/Trim Position 
B 
Everything in A, plus can be connected to a 4 to 20 mA current source 
sender (e.g., Rotax P/N 956413 Honeywell and Rotax P/N 456180 oil 
pressure sensors) 
C 
Everything in A, plus Dynon’s Capacitance-to-Voltage Converter and 
other senders with active voltage output hardware. Type C inputs can 
measure 0-5V DC, but can accept up to 15V DC without damaging the 
input (any voltage above 5V is seen as 5V, however). 