Installation guide
   SV-EMS-220/221 Installation and Configuration 
SkyView System Installation Guide - Revision R    7-9 
Pin 
Rotax 912 
Harness 
(except 912 iS) 
(100399-004) 
4-cyl Harness 
(100399-001) 
6-cyl Harness 
(100399-002) 
Wire 
Color 
Function 
Sensor Config 
1 
Do not connect 
2 
 
Red 
CHT 6 
J thermocouple 
3 
 
Red 
EGT 6 
K thermocouple 
4 
 
Red 
CHT 5 
J thermocouple 
5 
 
Red 
EGT 5 
K thermocouple 
6 
 
 
Red 
CHT 4 
J thermocouple 
7 
 
 
Red 
EGT 4 
K thermocouple 
8 
 
 
Red 
CHT 3 
J thermocouple 
9 
 
 
Red 
EGT 3 
K thermocouple 
10 
 
 
Red 
CHT 2 
J thermocouple 
11 
 
 
 
Red 
EGT 2 
K thermocouple 
12 
 
 
Red 
CHT 1 
J thermocouple 
13 
 
 
 
Red 
EGT 1 
K thermocouple 
14 
 
White 
CHT 6 
J thermocouple 
15 
 
Yellow 
EGT 6 
K thermocouple 
16 
 
White 
CHT 5 
J thermocouple 
17 
 
Yellow 
EGT 5 
K thermocouple 
18 
 
 
White 
CHT 4 
J thermocouple 
19 
 
 
Yellow 
EGT 4 
K thermocouple 
20 
 
 
White 
CHT 3 
J thermocouple 
21 
 
 
Yellow 
EGT 3 
K thermocouple 
22 
 
 
White 
CHT 2 
J thermocouple 
23 
 
 
 
Yellow 
EGT 2 
K thermocouple 
24 
 
 
White 
CHT 1 
J thermocouple 
25 
 
 
 
Yellow 
EGT 1 
K thermocouple 
Table 15–SV-EMS-220/221 Female D25 Pin-to-Sensor Compatibility 
The Rotax harness only has EGTs 1 and 2 wired, as the EMS measures the Rotax-supplied 
resistive CHTs through its GP inputs. The four-cylinder harness only has EGTs 1 through 4 and 
CHTs 1 through 4 wired. On the supplied harness, each pair of wires is encased in brown 
insulation and labeled with corresponding cylinder number. Inside the outer insulations, each 
wire in the pair has the color listed in Table 15 and Figure 29. 
If you make a custom thermocouple harness, note that all differential 
thermocouple inputs on the D25 and the D37 (SV-EMS-220 only) connectors are 
compatible with both J and K type thermocouples. Note that you will need to 
configure SkyView to support any installations that are not already supported in 
the preconfigured downloadable resources. 