Installation guide
   SV-EMS-220/221 Installation and Configuration 
SkyView System Installation Guide - Revision R    7-39 
For signals that have a peak voltage of 12V or lower —such as Light Speed ignition outputs—
use the low voltage RPM inputs. These inputs require that the peak voltage goes at least 2.1 
volts above ground, and crosses back down below 0.8V relative to ground to be counted as a 
pulse. 
For signals that have a peak voltage of 10-12V, either the Standard or Low Voltage RPM inputs 
can be used. 
Like the other methods above, you must know the number of pulses per revolution for your 
RPM transducer. 
Manifold Pressure Sensor 
The Dynon Avionics Manifold Pressure Sensor (P/N 100434-000) is an integral assembly 
consisting of three pins, a rubber seal, and a connector housing. Strip 3/16” insulation off the 
ends of the three wires listed at right. Slide the three rubber seals onto the three wires and the 
pins onto the ends of the wires. Crimp the 3 included pins onto the ends of the wires, ensuring 
that the long tabs that cradle the rubber seal wrap around the seal (see picture at right for 
example). For more details on preparing and crimping the Weather Pack pins, see 
http://www.whiteproducts.net/faqs.shtml. 
Pin 
Weather 
Pack Pin 
Color 
Function 
18 
C 
White/red 
+5 volt 
Auxiliary 
26 
B 
Green/red 
Manifold 
pressure 
17 
A 
Black 
Ground 
Note that you may need access to the SV-EMS-220/221’s +5 volt auxiliary supply for other 
sensor installations, so make allowances for breaking out the connection to other areas. Route 
the three wires to the location where you would like to mount the manifold pressure sensor. 
Plug the crimped pins into the included Weatherpack connector. Now, mount the manifold 
pressure sensor in a secure fashion using the mounting holes on either side of the sensor. 
The pressure port on the manifold pressure sensor requires 1/4” inner diameter tubing for a 
secure fit. You may need to use adapters to convert down to smaller inner diameter tubing for 
your specific engine. We recommend that you use pipe clamps at every transition point, 
including at the sensor itself. 
Table 35–Manifold Pressure Sensor Pins 
Figure 34–Detail view of properly 
crimped pin. 
C 
B 
A 
Figure 33–Pin insertion 
(rear) view of supplied 
connector. 
C 
A 
B 
Figure 32–Connection diagram for 
sensor with all black wires only 