Installation guide
SV-EMS-220/221 Installation and Configuration    
7-60    SkyView System Installation Guide - Revision R 
Hobbs time is a simple timer that runs whenever the oil pressure is above 15 PSI or the engine 
is above 0 RPM. 
If you have connected an External Alarm Light to SV-EMS-220/221 pin 29, the Alarm Light 
setting determines how the light behaves after alarm acknowledgement. It can be set to either 
SOLIID AFTER ACK, which leaves the light lit continuously after acknowledgement (until the 
alarm condition ceases) or OFF AFTER ACK, which turns the light off after an alarm has been 
acknowledged. 
Rotax 912 Behavior 
Setting ENGINE TYPE to ROTAX 912 pre-configures some engine settings for a Rotax 912 engine. 
SkyView will automatically configure and dynamically change the oil temperature and 
tachometer scales and alert thresholds in accordance with Rotax’s recommended ranges, 
described in detail below. When this mode is selected, EMS SETUP > SENSOR SETUP > OIL 
TEMPERATURE AND TACHOMETER settings are unavailable. 
Tachometer for Rotax 912: 
When OIL TEMP < 120ºF, the TACHOMETER displays these ranges: 
  0-1400 and 4000-6000 RPM in RED 
  1400-1800 and 2500-4000 RPM in YELLOW 
  1800-2500 RPM in GREEN 
When OIL TEMP > 120ºF, the TACHOMETER displays different ranges: 
  0-1400 and 5800-6000 RPM in RED 
  1400-1800 and 5500-5800 RPM in YELLOW 
  1800-5500 RPM in GREEN 
At 0 RPM, tachometer alerting is inhibited. When RPM advances above 0, the tachometer alert 
is inhibited for 10 seconds to avoid nuisance alarms as the engine starts.  
The alarm type for the tachometer is the “self-clearing” type. 
Oil Temperature Gauge for Rotax 912: 
When OIL TEMP < 190ºF, the OIL TEMP gauge displays these ranges: 
  100-120 and 230-266º F in YELLOW 
  120-190º F in GREEN if OIL TEMP has been above 190º F “more recently” than OIL TEMP was 
below 120º F; otherwise 120-190º F is displayed in BLACK OUTLINED IN WHITE 
  190-230º F in GREEN 
  266-280º F in RED. 
When OIL TEMP is > 190º F, the OIL TEMP gauge will display different ranges: 
  100-120 and 230-266º F in YELLOW 
  120-230º F in GREEN 
  266-280º F in RED 