7-66    SkyView System Installation Guide - Revision R 
  PRESET FUEL CAPACITY – this can be used to quickly recall a second, non-full starting fuel 
state. For example, if your tanks have tabs so that you can easily fill to ¾ of your normal full 
fuel load, you would enter this number here so that you can quickly set your fuel computer 
to this second preset when you fill to the tabs. 
  FUEL ADDED DETECT – When set to yes, SkyView will check for discrepancies between the 
physical fuel quantity senders and the fuel computer’s calculated fuel load on boot-up. If 
one is found, SkyView will prompt the user to adjust the fuel computer’s fuel state. 
  FUEL TANK REMINDER – SkyView can be configured to alert the pilot to switch their fuel 
tanks at a set time or fuel usage interval (based on the fuel computer’s fuel calculations). 
When enabled, it will periodically annunciate a “Switch Fuel Tank” alert message and audio 
alert. There is no visible counter for this timer. To configure this feature, set FUEL TANK 
REMINDER to either TIME or QUANTITY. Then, set the resulting FUEL REMINDER TIME or 
FUEL REMINDER AMOUNT setting to the desired reminder interval. 
Manual EMS Sensor Settings Configuration 
Go to the Sensor Setup Menu (SETUP MENU > EMS SETUP > SENSOR SETUP) to manually 
configure the settings of an EMS sensor. Once there, a list of every mapped sensor is displayed. 
Follow this basic procedure to configure sensor settings: 
1.  Choose a sensor. Scroll through the menu to a sensor and move the joystick right to 
enter to the sensor configuration menu. 
2.  Set the alarm. Scroll to the ALARM configuration line, move the joystick right to enter 
the Alarm Adjust Menu, choose the appropriate alarm for the sensor, and then press 
ACCEPT. Press BACK to return to the sensor configuration menu. 
3.  Set the graphical display limits. Scroll to the MAXIMUM and MINIMUM GRAPHICAL 
DISPLAY lines, move the joystick right to enter the respective menus, adjust the values 
appropriately - and then press ACCEPT. Press BACK to return to the sensor configuration 
menu. 
4.  Set the ranges. Scroll the menu and configure enable, color, and top and bottom. 
5.  Save the settings. Press BACK to return to the Sensor Setup Menu. Press EXIT to return 
to the Main Menu. 
The examples on the following pages show four configured sensors: a voltmeter, a contact, 
RPM, and an oil temperature sensor. 