Installation guide
   SV-EMS-220/221 Installation and Configuration 
SkyView System Installation Guide - Revision R    7-69 
Example RPM Setup 
Assume this sensor was mapped on the Sensor Input Mapping Wizard as: 
PIN # 
FUNCTION 
SENSOR 
NAME 
C37 P32/34 
RPM 
RPM 
RPM 
Now, we want to configure its alert and graphical properties. Go to the Sensor Setup Menu and 
open the RPM Page (SETUP MENU > EMS SETUP > SENSOR SETUP > RPM RPM). 
Configure RPM with the following properties: 
  ALARM:  OFF 
  MAXIMUM GRAPHICAL DISPLAY:  3000 RPM 
  MINIMUM GRAPHICAL DISPLAY:  0 RPM 
  SHOW SENSOR UNITS  YES 
  RANGE 1 
o  ENABLE  YES 
o  COLOR  GREEN 
o  TOP  2000 RPM 
o  BOTTOM  0 RPM 
  RANGE 2 
o  ENABLE  YES 
o  COLOR  YELLOW 
o  TOP  2250 RPM 
o  BOTTOM  2000 RPM 
  RANGE 3 
o  ENABLE  YES 
o  COLOR  GREEN 
o  TOP  2700 RPM 
o  BOTTOM  2250 RPM 
  RANGE 4 
o  ENABLE  YES 
o  COLOR  YELLOW 
o  TOP  2750 RPM 
o  BOTTOM  2700 RPM 
  RANGE 5 
o  ENABLE  YES 
o  COLOR  RED 
o  TOP  3000 RPM 
o  BOTTOM  2750 RPM 
Figure 48–Anatomy of a 
Widget: RPM 