Installation guide
SV-EMS-220/221 Installation and Configuration    
7-70    SkyView System Installation Guide - Revision R 
Example Oil Temperature Sensor Setup 
Assume this sensor was mapped on the Sensor Input Mapping Wizard as: 
PIN # 
FUNCTION 
SENSOR 
NAME 
C37 P7 
TEMPERATURE 
5/8”-18 NPT FLUID TEMP (100409-000) 
OIL 
Now, we want to configure its alert and graphical properties. Go to the Sensor Setup Menu and 
open the OIL TEMPERATURE Page (SETUP MENU > EMS SETUP > SENSOR SETUP > OIL 
TEMPERATURE). 
Configure OIL TEMPERATURE with the following properties: 
  ALARM:  LATCHING 
  MAXIMUM GRAPHICAL DISPLAY:  260 °F 
  MINIMUM GRAPHICAL DISPLAY:  80 °F 
  SHOW SENSOR UNITS  YES 
  RANGE 1 
o  ENABLE  YES 
o  COLOR  YELLOW 
o  TOP  165 °F 
o  BOTTOM  80 °F 
  RANGE 2 
o  ENABLE  YES 
o  COLOR  GREEN 
o  TOP  220 °F 
o  BOTTOM  165 °F 
  RANGE 3 
o  ENABLE  YES 
o  COLOR  YELLOW 
o  TOP  240 °F 
o  BOTTOM  220 °F 
  RANGE 4 
o  ENABLE  YES 
o  COLOR  RED 
o  TOP  260 °F 
o  BOTTOM  240 °F 
  RANGE 5 
o  ENABLE  NO 
o  COLOR  RED 
o  TOP  5 °F 
o  BOTTOM  0 °F 
Note that oil temperature is configured with a latching alarm in this example. If oil 
temperature ever reaches a range configured as red, an alarm will trigger and a 
Figure 49–Anatomy of a 
Widget: Oil 
Temperature 