Installation guide
Introduction     
1-2    SkyView System Installation Guide - Revision R 
Dynon Avionics Product Registration 
Please take a moment to register your Dynon Avionics SkyView system at 
http://register.dynonavionics.com. Registering your product with Dynon ensures that your 
contact information is up-to-date. This helps verify product ownership, can expedite warranty 
claims, and allows us to notify you in the event a service bulletin is published for your product. 
You can also optionally sign up to receive other Dynon news and product announcements. 
Dynon will not share your contact information with third parties or send you announcements 
without your explicit consent. 
About this Guide 
In the electronic (.PDF) version of this guide, page and section references in the Table of 
Contents and elsewhere act as hyperlinks taking you to the relevant location in the guide. The 
latest electronic version (.PDF) of this guide is available on the Dynon Avionics website at 
http://docs.dynonavionics.com. 
This icon denotes information that merits special attention. 
This icon denotes a helpful installation tip. 
Getting Started 
This “getting started” section contains a very small amount of information that can be used to 
check out your SkyView system on the bench, or immediately after SkyView has been installed 
in the plane. This is not a substitute for reading the entire SkyView System Installation Guide, 
which provides instructions for wiring and configuring SkyView to the unique requirements of 
your particular airplane. 
1.  A SkyView display requires 10-30 VDC. You must connect BOTH of the (long) Red wires 
to POWER and BOTH of the (long) black wires to Ground. Current for each display can be 
up to 3.5A @ 12V (add 1.5A if the SV-BAT-320 battery is connected and being charged), 
so use a big battery or power supply. 
2.  To power on or power off a SkyView display manually, push and hold Button #1 (the 
left-most button). 
3.  Any devices connected to SkyView that do not receive their power from the SkyView 
Network (such as SV-XPNDR-261/262 and Dynon Autopilot servos) must also be 
powered ON to communicate with SkyView. 
4.  To finish the installation of the SV-NET-10CP (10 foot) and longer cables, the diagram 
you need to insert the pins is SkyView Network Connection Pin-Out in Appendix C: 
Wiring and Electrical Connections. 