Installation guide
   Autopilot Servo Installation, Configuration, and Calibration 
SkyView System Installation Guide - Revision R    10-11 
Servo Electrical Installation 
Dynon Avionics’ servos are supplied with 7 unterminated wires, each about 8” in length. We 
recommended that you use the SV-NET-SERVO (one per servo) network cabling kit when 
installing servos; however, it is ultimately the responsibility of the installer to decide on 
connectors and associated wiring. 
Table 42 describes servo wire colors and functions. 
Color 
Function 
SV-NET-SERVO 
D9 Pin 
Notes 
Red 
Power 
N/A 
10 to 30 volts DC* 
Black 
Aircraft Ground 
N/A 
Can be locally grounded 
Green 
SkyView Network 
Data 1 A 
1 
Connected in parallel with 
other SkyView Network 
devices 
Blue 
SkyView Network 
Data 1 B 
6 
Connected in parallel with 
other SkyView Network 
devices 
Yellow 
AP 
Disengage/Control 
Wheel Steering 
(CWS) Button 
N/A 
Connected through a 
normally-open pushbutton 
switch to Ground (disengages 
AP when button is pushed). If 
two servos are installed, the 
yellow wire from each servo is 
connected in parallel to a 
single pushbutton. 
White/Green 
SkyView Network 
Data 2 A 
8 
Connected in parallel with 
other SkyView Network 
devices 
White/Blue 
SkyView Network 
Data 2 B 
4 
Connected in parallel with 
other SkyView Network 
devices 
Table 42–Detailed Servo Wiring 