Installation guide
   Autopilot Servo Installation, Configuration, and Calibration 
SkyView System Installation Guide - Revision R    10-15 
Considerations for External LEVEL Button 
in SkyView systems with multiple SkyView displays 
Prior revisions of the SkyView System Installation Guide recommended that in 
SkyView systems with multiple displays, for redundancy the External LEVEL Button 
should be connected to all SkyView displays in parallel. The following 
recommendations supersede that earlier guidance. 
Do not connect CONTACT 1 / LEVEL BUTTON inputs of multiple SkyView displays 
directly together. If you do so, when one display is powered off, it will cause 
displays that are powered on to see the CONTACT 1 / LEVEL BUTTON input as 
being pushed (the display powered off will “ground” the input). This could cause 
the unintentional activation of LEVEL mode or could prevent the External Level 
Button from operating. 
Installation options installing the External LEVEL Button on systems with multiple 
SkyView displays: 
1.  Connect the External LEVEL Button to only one display. The External LEVEL 
Button will operate for all displays in the SkyView system as long as the 
display the External LEVEL Button is wired to is powered on and operating 
normally. As a non-flight-critical function, the loss of the External LEVEL 
Button in some display failures may be acceptable for your installation. Use 
of the LEVEL function via the SkyView soft keys via any operating SkyView 
display is still possible, as well as pushing the LEVEL button on the 
(optional) SV-AP-PANEL. 
2.  Install a diode for each individual display’s connection to the External 
LEVEL button. The diode should be installed with the cathode end (painted 
band on the diode) oriented towards the External LEVEL button, and 
should be installed in-line with the contact wire between the SkyView 
display and the External LEVEL button. One diode is needed per display. 
Any diode will work for this application. An example diode is the very 
common 1N914, available from Radio Shack (P/N 276-1122). With a diode 
installed for each display, the External LEVEL Button will work correctly 
with any combination of displays powered on and powered off. 
3.  Use a multi-pole pushbutton (momentary, normally open / push to close) 
for the External LEVEL Button. With this option, run each display's 
connection to a different pole on the pushbutton. With the multi-pole 
pushbutton installed, the External LEVEL Button will work correctly with 
any combination of displays powered on and powered off. 
Wire Sizing 
While it is beyond the scope of this installation guide to advise on specific types of wiring for a 
particular aircraft, choice of wiring should be sized to 1) minimize voltage drop over the length 
of the particular wiring run, and 2) conduct the amount of current required by the subsystem 