Installation guide
  SV-XPNDR-261/262 Installation, Configuration, and Testing 
SkyView System Installation Guide - Revision R    11-13 
The following table is a guide to the maximum usable lengths of some common cable types. 
Actual cable loss varies between manufacturers, there are many variants, and the table is 
therefore based on typical data. Use it as a guide only and refer to the manufacturer’s data 
sheet for your specific chosen cable for accurate values. 
Max Length 
in Meters 
Max 
Length 
in Feet 
Insertion Loss 
dB/meter at 
1090MHz 
MIL-C-17 
Cables 
Electronic 
Cable 
Specialists 
Type 
SSB 
Electronic 
2.54 
8’ 4” 
0.59 
M17/128 
(RG400) 
3.16 
10’ 4” 
0.47 
3C142B 
3.81 
12’ 6” 
0.39 
M17/112 
(RG304) 
4.50 
14’ 9” 
0.33 
Aircell 5 
5.25 
17’ 3” 
0.29 
M17/127 
(RG393) 
311601 
6.42 
21’ 1” 
0.23 
311501 
6.81 
22’ 4” 
0.22 
Aircell 7 
8.22 
26’ 11” 
0.18 
311201 
12.59 
41’ 3” 
0.12 
310801 
Contact Electronic Cable Specialists on +1 414 421 5300 or at www.ecsdirect.com for their data 
sheets. Contact SSB-Electronic GmbH on +49-2371-95900 or at www.ssb.de for their data 
sheets. 
When routing the cable, ensure that you: 
  Route the cable away from sources of heat. 
  Route the cable away from potential interference sources such as ignition wiring, 400Hz 
generators, fluorescent lighting and electric motors. 
  Allow a minimum separation of 300 mm (12 inches) from an ADF antenna cable. 
  Keep the cable run as short as possible. 
  Avoid routing the cable round tight bends. 
  Avoid kinking the cable even temporarily during installation. 
  Secure the cable so that it cannot interfere with other systems. 