Installation guide
 SV-ARINC-429 Installation and Configuration   
12-2    SkyView System Installation Guide - Revision R 
Additional mounting location, orientation, and other installation requirements are described in 
the System Planning section earlier in this manual. Please review this section when physically 
installing your with SV-ARINC-429 module(s). 
Dynon does not provide mounting hardware with SV-ARINC-429 module. The mounting tabs on 
each side of the module have holes sized for #10 fasteners, but it is up to the installer to decide 
how the SV-ARINC-429 will be secured to the aircraft. 
Follow recommended torque practices when tightening the mounting hardware. Do not rivet 
the SV-ARINC-429 to the aircraft as this will hinder future removal if necessary. 
SkyView Network Connection 
Connect the SV-ARINC-429 module to the SkyView network using the hardware mentioned in 
the SkyView System Construction Section or using equivalent hardware. 
If you have to install a connector on the end of a network cable, insert all pins into the D9 
connector. Refer to Appendix C: Wiring and Electrical Connections for details on connector pin-
outs and wire colors. 
Remember to configure the network as described in the Network Setup and Status 
section after connecting all modules to a display. 
ARINC-429 Device Connection 
Harness Construction 
Because the SV-ARINC-429 can be connected to a variety of devices, the harness requirements 
will vary from airplane to airplane. Therefore, Dynon Avionics does not supply pre-
manufactured harnesses for the SV-ARINC-429 module. Instead, your SV-ARINC-429 shipped 
with enough connectors and pins to generate a wide variety of harness configurations. Refer to 
the sections below for detailed wiring information. 
If you do not own a D-sub machined-pin crimping tool, they can be obtained for under $50 from 
many retailers. See http://wiki.dynonavionics.com/Tools_not_supplied_by_Dynon for known 
sources of these products. You may also find it helpful to own a pin insertion/extraction tool as 
well. 
Additional harness construction and wiring information can be found in Appendix C: Wiring and 
Electrical Connections. 
The SV-ARINC-429 has a single 25 pin female D-Sub socket which is used for all data 
connections to your compatible ARINC-429 device. The pin out depicted in Figure 81 below 
depicts the view from the rear of your male D25 connector – the view you will have of your 
harness connector as you are inserting pins into the harness. Note that the pin numbers are 
labelled on the face of both the female and male connector. 