Installation guide
 Vertical Power VP-X Integration and Configuration   
13-4    SkyView System Installation Guide - Revision R 
The VP-X settings in the SETUP MENU > VP-X SETUP menu mainly concern how information 
from the VP-X is displayed in SkyView: 
  MAIN BATTERY WARNINGS: Sets the main battery voltage levels at which caution and 
warning indications are provided visually on the VP-X page. 
  AUX BATTERY WARNINGS: Sets the auxiliary battery voltage levels at which caution and 
warning indications are provided visually on the VP-X page. If you do not have an 
auxiliary aircraft battery (note that this is NOT the SkyView SV-BAT-320) installed, this 
setting can be ignored. 
  SYSTEM AMPS: Sets the current levels for the entire electrical system at which caution 
and warning indications are provided visually on the VP-X page. 
  ALTERNATOR AMPS: Sets the current levels for the alternator at which caution and 
warning indications are provided visually on the VP-X page. 
  BATTERY AMPS: Sets the discharge rate at which caution and warning indications are 
provided visually on the VP-X page. 
  SKYVIEW AMPS SHUNT LOCATION: Depending on your electrical layout, your SkyView 
shunt may be in one of a few places in your electrical system. 
  AILERON TRIM POSITION / ELEVATOR TRIM POSITION / FLAP POSITION: Set to SkyView 
EMS if your trim and/or flaps position signal input is routed to your SV-EMS-220/221 
module, or to VP-X if it is connected to your VP-X system instead. If set to VP-X, the 
engine page trim and/or flaps widgets will be sourced from the VP-X position 
information. Note that even when using the VP-X as your trim and/or flaps position 
source, you do still need to perform the SkyView-based calibration routine for the trim 
information to display properly in SkyView. These calibrations can be found under 
SETUP MENU > HARDWARE CALIBRATION > EMS CALIBRATION. You do not need to 
perform that VP-X Configurator-based calibration. However, set all of the points in the 
VP-X Configurator to “1”. 
  To display a battery voltage widget that displays battery voltage connected to the VP-X, 
go to SETUP MENU > EMS SETUP > SCREEN LAYOUT EDITOR > (xx % PAGE) > SENSOR 
(button) > BATT VOLTS (VP-X) > ACCEPT (button) > STYLE (per your preference) > SIZE 
(per your preference) > SAVE (button). 
Post Installation Checks 
  Follow all installation, configuration, and test procedures as instructed by the Vertical 
Power documentation. 
  Ensure that your VP-X system is powered on and functioning normally. 